Controls, connectors, indicators (see figure 1), Model fp410 figure 1 – Shure FP410 User Manual

Page 2

Advertising
background image

2

MODEL FP410

FIGURE 1

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

4

3

2

LINK

FP410

TAPE OUT

MIC LINE

MIC LINE

MIC LINE

MIC LINE

MIC LINE

MIC LINE

PHANTOM

OFF ON

OUT

IN

MASTER

PULL FOR 1 KHZ TONE

BATTERY TEST

MANUAL AUDIO

LIMITER IN

PULL FOR MONITOR

OFF ON

PEAK

VU

100%

MONITOR IN

4

3

2

1

PHONES

1

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

--20 --10 --7 --5 --3 --2 --1

0

+1 +2 +3

--24 --20 --16 --12 --8 --4

0 +4 +8 +12 +16

Selectable Off--Attenuation control for seamless operation

Automatic gain adjustment as additional microphones are
activated

Defeatable “Last Mic Lock--On” circuit keeps at least one mi-
crophone on at all times—maintains acoustic ambiance and

prevents confusing background sound changes

Wide, flat frequency response and low distortion up +18
dBm output

Linking capability for systems containing over 25 mixers
and over 100 microphones

LED indication of microphone channel mix levels, output
level, and limiter action

Automatic muting prevents annoying thumps and loud-
speaker damage when unit is turned on and off

Transformer--balanced inputs and outputs switchable to
line-- or microphone--level

Separate monitor input and tape output (aux--level) jacks

Front--panel headphone monitor jacks with level control

Front--panel auto--disable switch for manual operation

Operates from ac mains voltage or two 9 V batteries

Switchable 14 V and 48 V phantom powering for condenser
microphones

Underwriters Laboratories Listed and Canadian Standards
Association listed as Certified (FP410 only)

CONTROLS, CONNECTORS, INDICATORS
(See Figure 1)

1. Microphone Channel Gain Controls 1--4: At “0” position, mi-

crophone channel is removed from operation. Turning control

clockwise activates microphone channel and allows adjust-

ment of microphone level.
2. Input Normal Green LED: Should flicker with normal speech

levels.
3. Input High Red LED: Should flicker only on loud speech

peaks.
4. Flat (

)/Low--Cut (

) Slide Switches: Provide low--fre-

quency rolloff to reduce undesirable low--frequency signals

such as wind noise.
5. MASTER Rotary Control: Determines the level of the com-

bined input signals at Mic/Line, Tape and Phones outputs.

PULL FOR 1 kHz TONE position activates 1 kHz tone oscilla-

tor (tone level is determined by Master control setting). Oscilla-

tor signal appears at all outputs. When oscillator is not in use,

knob should be pushed in.
6. PEAK/VU Output Level Meter: Meter function is selected by

adjacent PEAK/VU slide switch. In PEAK switch position, me-

ter indicates peak signal levels. In VU position, it indicates av-

erage signal levels, simulating a true VU meter.
7. BATTERY TEST Momentary Slide Switch: Operates in con-

junction with PEAK/VU Meter to indicate battery condi-

tion.With POWER switch on and switch in momentary--on po-

sition, new set of batteries lights all green LEDs. Number of

green LEDs lit indicates approximate battery life remaining

when alkaline batteries are used. NOTE: POWER LED begins

flashing when total battery supply voltage drops to 10 Vdc (one

green LED lit).
8. MANUAL/AUTO Slide Switch: Selects manual or automatic

microphone operating mode. In MANUAL position, unit oper-

ates as a conventional microphone mixer. In AUTO position,

unused microphones automatically turn off.