Shure FP410 User Manual

Page 7

Advertising
background image

7

Operating Voltage

AC Operation: 100 to 120 Vac rated nominal, 80 to 132 Vac
fully operational (FP410); 230 Vac rated nominal, 160 to 264
Vac fully operational (FP410E), 50/60 Hz, 8 W
DC Operation: 18 Vdc nominal at 25 mA typical no--signal,
33 mA typical at 0 VU (+4 dBm) output with 600

τ

load; 6 Vdc

minimum; battery life approximately 12 hours with alkaline
batteries at +4 dBm output in continuous use at room tem-
perature; two 9--volt batteries (type NEDA 1604A)

Temperature Range

Operating

--18

to 57

C (0

to 135

F )

. . . . . . . . . . . . .

Storage

--29

to 71

C (--20

to 160

F)

. . . . . . . . . . . . . . .

Overall Dimensions

44.5 mm H x 368 mm W x 210 mm D (1

3

/

4

x 14

1

/

2

x 8

1

/

4

in-

ches)(not including feet)

Net Weight

2.27 kg (5 lb)

Certifications

FP410: Listed by Underwriters Laboratories, Inc., listed as
Certified by Canadian Standards Association.
FP410E: Conforms to European Union directives, eligible to
bear CE marking;VDE GS-certified to EN 60 065; meets Eu-
ropean Union EMC Immunity Requirements (EN 50 082-1,
1992).

Questions & Answers

Questions about your FP410 installation? This section lists

the most common questions asked about Shure’s automatic

microphone systems. Maybe your question is among the fol-

lowing. If not, contact Shure’s Customer Service Department.
Q. Why don’t I get any sound output from my FP410?
A. Assuming that your power amp, tape deck, speakers, etc.

are good, possibly it’s because:

The Channel or Master Gain controls are turned down,

A microphone is not connected,

A rear--panel Mic/Line input or output switch or the Phan-

tom On--Off switch is improperly set,

The FP410 isn’t plugged in or doesn’t have batteries in-

stalled, or

The Power switch isn’t on.

Check these items and make the required correction.
Q. Still doesn’t work. Why?
A. Maybe you have a defective microphone or cable. While lis-

tening to headphones plugged into one of the front--panel

Phone jacks, try replacing the suspect microphone or cable

with one known to be good.
Q. Why does a microphone turn on or off erratically, causing

speech dropouts?
A. Excessive room noise (such as from air--handling or audio--

visual equipment) can be a cause. Reduce the room noise, the

proximity of the noise to any mic, and/or the talker--to--mic dis-

tance. A loud talker close to their microphone or with their

Channel Gain control set too high can sometimes inhibit prop-

er microphone activation by a “weaker” talker who is too far

from their microphone or has their Channel Gain control set

too low. Balance the microphones by repositioning and/or re-

setting the Channel Gain controls in accordance with the Op-

eration section.

IMPORTANT: Best results are generally obtained when the

Last Mic Lock--On is not defeated and the Off--Attenuation is

13 dB (modifiable function switches up). Difficult situations

may be aided by changing the Hold Time from 0.4 to 1.0 sec-

ond (modifiable function switch down).
Q. Why am I getting howling through my loudspeakers?
A. For the same reason that howling is present in any PA sys-

tem: your mics are picking up the speaker sound and reampli-

fying it. Move the speakers or mics, or turn down the gain con-

trols, to avoid the howling. Automatic operation does provide

more output level before howling than manual operation, but

the system still can howl.
Q. Why does the FP410 output sound distorted?
A. The Channel, Master or Phones Gain control may be set too

high. Set the Channel Gain according to the Operation section.

Set the Master Gain to avoid excessive red LED indications on

the Output Level meter, or switch the Limiter in. Turn down the

Phones control. Check the following equipment levels.
Q. Why does the speech level go up when I switch from Manu-

al to Automatic operation?
A. This is normal and proper operation for any automatic mix-

er.When switched to Automatic, the FP410 attenuates any in-

put channel not being used. Internally, this removes the inac-

tive channels from the FP410 mix bus. This action increases

the perceived level of any active input channel. For example,

the audio gain increase will be 6 dB when going from four to

only one activated microphone channel.
Q. Why is one of my four mics very noisy?
A. Assuming the mic is operating properly (you can check this

by substituting with another mic), you probably have a con-

stant noise source such as air--moving equipment or a defec-

tive fluorescent light ballast in the trouble area. This ambient

noise source can be unnoticed until it’s picked up by a mic:

then it’s extremely annoying. If you can’t repair, turn off or lower

the noise source, try relocating the mic to eliminate or at least

lower the noise. If this is not possible, use the FP410 in the

Manual mode to avoid microphone activation problems and

accept the noisy output.

Advertising