Siemens SIMATIC NET PROFIBUS User Manual
Page 390

Infrared Link Modul (ILM)
6ZB530–3AC30–0BA1
48
Copyright
by Siemens
Safety
VDE specifications
VDE 0806
=
EN60950 and IEC950
UL/CSA approval
Requirements are met
Climatic environmental conditions
Ambient temperature
0
°
C to
)
60
°
C
(IEC 68–2–1, IEC 68–2–2)
Storage temperature
–40
°
C to
)
70
°
C
(IEC 68–2–14)
Relative humidity
< 95% (none condensing)
(IEC 68–2–30)
If condensation forms on the window, there is a tempo-
rary reduction in the distance that can be covered.
There is no permanent functional disturbance and no
damage to the electronics if the threaded cable inlet ful-
fills the requirements of IP65.
Mechanical environmental conditions
Oscillation during operation
10 to 58 Hz, 0.075 mm deflection
58 to 150 Hz, 10 m/s
2
(1g) acceleration
(IEC 68–2–6)
Oscillation during transportation
5 to 9 Hz, 3.5 mm deflection
9 to 500 Hz, 10m/s
2
(1g) acceleration
Degree of protection
IP 65
Weight
800 g
Dimensions
175
Ч
80
Ч
58 mm
Casing material
Die-cast aluminum
Table 4:
Environmental Conditions for the Use of the PROFIBUS ILM