Programmable System Options

The following is a description of the programming options of the system. Some of the program branches

control more than one option, and may require accessing a particular branch number twice in order to

program all desired features.
1. Ignition Door Locking. Selects whether or not the system will automatically lock the doors 5 seconds

after the ignition key is turned on.

2. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when

the ignition is turned off. The Ignition Door Locking feature may be programmed to unlock all doors or

the driver’s door only. If driver’s door only is selected, the optional Passenger Unlock wire must be

connected. (

See Two Stage Door Lock Diagrams)

3. Door Unlock Pulse. Selects between one pulse or two pulse operation for the door unlock output.

Many new import vehicles’ factory door locking systems require two pulses on the proper wire to unlock

the doors. These systems can be interfaced directly without the use of relays or any additional circuitry

by programming the system for double unlock pulse.

4. Door Lock Pulse Length. Selects between a 1-second and a 3-second output for door locking and

unlocking. Program to 3 seconds for vehicles equipped with vacuum door locking systems.

5. Aux 2 Auto Activate with Lock. When selected, the Auxiliary 2 output will activate when the system

is locked. This feature can be used to roll-up windows, close sunroofs, activate accessories, etc.

6. Auxiliary 2 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 1.

Momentary operation provides an output for as long as the transmitter button is pressed.(1-way

remote)
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is

pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and remains

on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be

programmed to output for 1 second up to 255 seconds.

7. Unlock with Auxiliary 1. When selected, activating the Auxiliary 1 output (usually used to open the

trunk) will unlock the vehicle doors.

8. Aux 3 Mode. Selects between Aux 3 output or Factory re-arm output.

9. Start in Valet Mode. Selects whether or not the vehicle can remote start while in the valet mode.

10. Lock After Start. When selected, the doors will automatically lock after remote starting.

11. Lock After Shutdown. When selected, the doors will automatically lock after remote shutdown.

12. Engine Run Time. Selects between 15 or 25 minutes for the remote start run cycle.

13. Automatic Start Mode. Selects between every two hours or every hours for the automatic engine

starting feature.

14. Engine Sense Mode. Selects between Tachless and Tach Monitor operation.

Tachless. Determines the engine status using an advanced software routine, without requiring

connection to the vehicle’s tachometer. Tachless operation may not be compatible with some vehicles

or in severe temperatures, in which case the tach wire must be connected.
Tach Monitor. Monitors the vehicle’s tach wire (or a fuel injection wire) in real-time to determine engine

status and adjust starter crank time automatically. If programmed for Tach Monitor, the vehicle’s tach

signal will have to be learned before initial operation (see below).