INSTALLATION AND CONNECTIONS

3

English

15

When connecting multiple devices, it is necessary to make
termination settings on both end devices.
z

Set the RS-485 termination switch of both end devices to
ON.

z

Be sure to set the RS-485 termination switches of all
devices in between (devices other than the first and last
devices) to OFF.

z

If the termination settings are not correctly made, the
incorrect data is transmitted to each device.

Connect camera to the 2ND RS485/422 terminal with a
twisted-pair cable and perform settings in the <CAMERA
CONTROL SET> screen (JP.150) to control the camera with
the connected system controller or with the digital video
recorder.

z

Connect as shown above and set to full screen in the
<CAMERA CONTROL SET> screen to control camera with
the digital video recorder.

z

If connected as shown above, settings must be made in
<CAMERA CONTROL SET> screen.

z

Connect other companies’ cameras to the 2ND RS-485/
422 terminals.

1

Connect as above.

Connect SSP dome cameras to VIDEO IN 1 and 2.

2

Set the camera numbers and protocols

in the <CAMERA CONTROL SET>

screen. (JP.150)

3

Operate the dome cameras with the

front panel buttons. (JP.153)

RS-485 termination switch settings

RS-485

TERMINATE
OFF

ON

TERMINATE

RS-485

OFF

ON

TERMINATE

RS-485

OFF

ON

VIDEO

COM

SW

ON

1 2 3 4

A

B

TELEMETRY

12V

SW

ON

1 2 3 4

System controller

Termination
switch

Digital video recorder

RS485
Termination
switch

Example:

RS485
Termination
switch

Connecting to a 2ND RS485/422

terminal

Operation

Other companies’ cameras

System
controller

Advertising