Advanced menu set 9, Camera control set – Sanyo DSR-5716P User Manual

Page 210

Advertising
background image

ADVANCED MENU SET

9

English

209

Set when cameras with remote operation capability are
connected.
Perform the following connections and set camera control to
use in full screen display.
Connections necessary for remote operation:
z

Connect coaxial control cameras to the VIDEO terminal.

z

Connect the Sanyo RS-485 control camera to the RS-485
terminal (RJ-11).

z

Connect the other companies’ RS485/422 control camera
to the 2ND RS485/422 terminal.

1

Click the

button on the operation

panel.

The “MAIN MENU” is displayed.

2

Click “8. ADVANCED MENU SET”.

The “ADVANCED MENU SET” screen is displayed.

3

Click “2. CAMERA CONTROL SET”.

The “CAMERA CONTROL SET” screen is displayed.
The DSR-5709P displays only nine channels.

4

Set “PROTOCOL” to the protocol

corresponding to the dome camera.

[Settings] (‹ indicates default setting)

5

The address (000 to 127) is displayed in

“ADD”.

When “SANYO RS485” or “2ND RS485/422” is specified as
the protocol, the address is displayed automatically.

6

To “ACTION”, specify an interlocking

behavior of camera to be exhibited

when an alarm is detected.

You can control the behavior of the camera such as alarm-
triggered lens orienting, and pan and tour movement.

[Settings] (‹ indicates default setting)

z

For “PRESET”, you can set “PRESET2-9” with DSR-5709P
and “PRESET2-16” with DSR-5716P.

z

Actually available actions depend on each camera. For
more information, refer to the camera's instruction manual.

7

Use the same procedure to set the other

channels.

8

Set “2ND RS-485/422 PROTOCOL”.

[Settings] (‹ indicates default setting)

‹

OFF, BBV, KALATEL, PELCO, SENSORMATIC

9

Set “DATA SPEED”.

[Settings] (‹ indicates default setting)

‹

9600bps, 4800bps, 2400bps

10

Click [SAVE].

The setting is saved.

2. CAMERA CONTROL SET

Setting

Description

‹

OFF

No protocol

SANYO RS485

SANYO RS485

BBV COAX

BBV COAX
(Also supports AUX commands.)

PELCO COAX

PELCO COAX

2ND RS-485/422

2ND RS-485/422

COAX (H-SSP)

COAX (H-SSP)

5

4

8

10

6

9

Setting

Description

‹

OFF

No action triggered.

PRESET

Moves the camera lens to the angle
corresponding to your selected preset
number.

PAN

Starts automatic panning.

TOUR

Starts tour.

SEQUENCE

Starts sequence.

Advertising
This manual is related to the following products: