Warning, Electrical connection – Siemens WTXD5522UC User Manual

Page 6

Advertising
background image

6

Installation location

d

WARNING

d

Do not install the dryer:

- outdoors,
- in an environment with dripping

water,

- near flammable materials,
- in rooms which are at risk of frost,
- in rooms which may contain gas

or other fuels,

- in cupboards with lockable doors

or in alcoves.

- with other fuelĆburning appliance

in the same closet.

The installation room must be well

ventilated, otherwise the dryer will

operate below optimum performance.
Do not operate the dryer at

temperatures above 104

°

F (40

°

C) and

below 41

°

F (5

°

C). Low temperatures

affect the automatic program sequence

and may prolong the drying times.
The installation surface for the dryer

must be clean, level and firm. Do not

install the appliance on carpets!

Compensate for uneven floors with the

heightĆadjustable feet.
Install the dryer and level side to side

and front to back. Use a bubble level.

Never remove the heightĆadjustable

feet!
The size of the installation area

depends on the dimensions of the

dryer. Ensure that there is adequate

room for the swivel range of the door!

d

WARNING

d

If installed in a garage, the dryer

must be installed on a substantial

platform at least 18 inches above

the floor to reduce the liklihood of

igniting flammable vapors and be

located or protected so it cannot be

damaged by a moving vehicle

Dimension

Weight

a

27.0" (686 mm)

125 lbs

(56 kg)

b

31.8" (808 mm)

125 lbs

(56 kg)

with

c

37.2" (945 mm)

with

packaging

d

angle

19.7" (500 mm)/

170-180°

packaging

143 lbs

(64 kg)

If installing the dryer in a closet, observe

the minimum distances according to

the following table:
Minimum Installation Clearances

Closet

Sides

0" (O mm)

Top

12" (3O5 mm)

Rear*

0" (O mm)

* as close to wall as gasĆpiping and venting
will allow.
Important information concerning

minimum distances:
-

Depending on the location of the

exhaust air connection, an

additional minimum distance of

5½ inch (14 cm) must be provided

on this side for pipes/brackets (see

page 9).

-

Distances above the indicated

minimum dimensions reduce the

risk of mold formation behind the

appliance.

-

Additional distances reduce noise

transmission.

-

Additional distances facilitate

installation and service.

-

If the dryer is installed in a small

room, the doors of the room must

be fitted with vents of a specified

minimum size.

The dryer door is delivered with hinges

on the right. If required, the door hinges

can be switched to the left side.
If the door hinges are to be changed

over, please contact your dealer or our

customer service team (see page 22).

Electrical connection

GROUNDING INSTRUCTIONS

This appliance must be grounded. In

the event of a malfunction or

breakdown, grounding will reduce the

risk of electrical shock by providing a

path of least resistance for the electric

current. This appliance features a cord

with an equipmentĆgrounding

conductor and a grounding plug. The

plug must be plugged into an

appropriate outlet which has been

properly installed and grounded in

accordance with all local regulations

and ordinances.

d

WARNING

d

Improper connection of the

equipment grounding conductor

may result in electric shock. Have

the appliance checked by

a qualified electrician or service

technician if you are in doubt as to

whether the dryer has been properly

grounded.

Do not modify the plug provided with

the appliance - if it will not fit in the

outlet, have a proper outlet installed by

a qualified electrician or exchange the

cord with an appropriate one rated for

the dryer.

Advertising