Warning, Gas connection – Siemens WTXD5522UC User Manual

Page 7

Advertising
background image

7

d

WARNING

d

The dryer must only be connected

to an individual branch circuit via a

socket which has been properly

installed and grounded.

The household electrical voltage must

correspond to the voltage specification

on the dryer (rating plate).
You will find the rating plate on the

inside of the front panel.

Connection specifications as well as

the electrical requirements are

stipulated on the appliance nameplate.
Make sure that:
-

the power cord plug fits into the

socket.

-

the power cord is acceptable for

use in this application.

-

the grounding system is properly

installed.

The power cord may be replaced by an

electrician only.

Replacement power cords are available

from Customer Service.

Volts

Hertz

Amperes

Watts

110-120

60

9

1080

Gas connection

d

WARNING

d

TO AVOID Explosion hazard!

Use a new AGA or CSA approved

gas supply line.

Install a shutĆoff valve.

Securely tighten all gas

connections.

Have a qualified person make sure

gas pressure does not exceed

14 in. W.C./ 3.49 kPa/ 0.506 psig.

(Natural and Propane Gas).

Example of a qualified person

include:

-

licensed heating personnel,

-

authorized gas supplier personnel,

-

authorized service personnel.

Failure to do can result in explosion

or fire.

Risk of death or injury!

All gas line connections must be

tested for leaks prior to appliance

operation. Apply soapy water to gas

line connections and check for

formation of new bubbles. Bubbles

indicate leak!

When installing the gas supply to the

gas dryer inlet pipe, do not exceed 310

lbf in (35 Nm).

d

WARNING

d

Never use an open flame to test for

gas leaks.

Gas type

This gas dryer when equipped for use

with NATURAL GAS, will employ an

orifice size 46 and have a gas outlet

pressure of 3.5 in. W.C. This gas dryer

when equipped for use with PROPANE

GAS, will employ an orifice size of 1.21

mm, and have a gas outlet pressure of

11 in. W.C.
Your dryer must have the correct valve

for the type of gas in your home. Valve

information is located on the rating

plate behind the door below the drum.
If the ratingĆplate information does not

agree with the type of gas available,

contact your dealer or our customer

service team (see page 22).

Gas supply line

1

/

2

" I.D. pipe is recommended.

3

/

8

" approved tubing is acceptable for

lengths under 20 ft (6.1 m) if local

codes and gas supplier permit.
Must include

1

/

8

" NPT plugged

tapping, immediately upstream of the

gas connection.
A shut off valve must be included:
-

USA:

An individual manual shutĆoff valve

must be installed within 6 ft (1.8 m)

of the dryer in accordance with the

National Fuel Gas Code, ANSI

Z223.1.

-

Canada:

An individual manual shutĆoff valve

must be installed in accordance

with the B149, Installation Codes,

CAN/CSA B149.1 and CAN/CSA

B149.2. It is recommended that an

individual manual shutĆoff valve be

installed within 6 ft (1.8 m) of the

dryer.

1111

5

1

2

3

4

1 ć

1

/

2

" NPT gas supply line

2 ć Gas shutĆoff valve

3 ć

1

/

8

" NPT plugged tapping

4 ć

3

/

8

" pipe to flare adapter fitting

5 ć

3

/

8

" flexible gas connector (to the dryer)

The shutĆoff valve should be easy to

reach for opening and closing.
Note:

The dryer must be checked for proper

operation whenever the gas

connections have been broken.