Caution, Warning, Exhaust air connection – Siemens WTXD5522UC User Manual

Page 8

Advertising
background image

8

Dryer gas pipe

The gas pipe that comes out through

the rear of the dryer has a

3

/

8

" male

pipe thread.

Connection of the dryer

d

CAUTION

Connection must be made by

a qualified technician.

The dryer must be disconnected

from the gas supply piping system

during testing pressure.

When using for the first time make

sure that there is no air in the piping

system.

d

WARNING

d

Do not use copper pipes and tubing

if connected to natural gas.

The connection may be different,

according to the supply line type, size

and location.
If local codes permit, use a flexible

stainless steel connector (Design

certified by the America Gas

Association or CSA International)

to connect the dryer.

1

2

To reduce the distance between body

sheet and wall install a

3

/

8

" elbow on

the gas pipe of the dryer.
1 ć gas pipe (

3

/

8

" male pipe thread)

2 ć

3

/

8

" elbow

Exhaust air connection

d

WARNING

d

1. To reduce the risk of fire, this dryer

MUST BE EXHAUSTED
OUTDOORS.

2. To reduce the risk of fire, do not

use ductwork longer than
recommended.

3. DO NOT use a plastic or

nonĆmetal duct with this dryer.

4. DO NOT use a duct smaller than 4

inches in diameter.

5. DO NOT use exhaust hoods with

magnetic latches.

6. DO NOT exhaust the dryer into a

chimney, furnace cold air duct,
attic, crawl space, or any other
ductwork used for venting.

7. DO NOT install a flexible duct in an

enclosed wall, ceiling or floor.

8. DO NOT crush or kink the duct.
9. Do clean and inspect the exhaust

system on a regular basis; at least
once a year.

10. The exhaust duct must terminate

in a manner to prevent back drafts
or entry of birds or other wildlife.

The Siemens dryer must be vented

outdoors. To prevent buildĆup of

moisture and accumulation of lint

indoors, as well as to maintain

maximum drying efficiency, it is

recommended that the dryer is vented

outdoors.

Exhaust air outlet on the dryer

The dryer is delivered with an exhaust

air outlet on the rear of the appliance.
To take account of the spatial

requirements and an existing exhaust

air system, the following connection

options are possible for the exhaust air

outlet:
-

on right side of the appliance,

-

on the underside of the appliance.

1

3

2

1 ć Exhaust air outlet on the rear of the

appliance (standard)

2 ć Exhaust air outlet on the side (optional)

3 ć Exhaust air outlet on the underside of the

appliance (optional)

Special exhaust air connections must

be obtained from our customer service

for either connection type (see

page 9).
-

Side air exhaust

-

Bottom air exhaust

A qualified technician should change

the exhaust air outlet to the optional

connection location.

Ductwork

To ensure optimum performance, the

ducting system of the dryer should be

as short as possible with a minimum

number of elbows. Your dryer will work

best when the venting system has as

few air flow restrictions as possible.

Exhaust ducting which is longer than

recommended may extend drying time,

cause lint to accumulate and affect

dryer performance and dryer life.
FourĆinch (approx. 100 mm) diameter

ducting should be used. Use either

rigid metal or flexible metal ducting

material. DO NOT

use plastic or

nonĆmetal duct with this dryer.
DO NOT assemble the ductwork with

screws or fasteners that extend into the

duct. They will serve as an

accumulation point for lint.

Joints should be secured with

aluminium tape.