Replacing the projection lamp – Sharp XG-NV4SU User Manual

Page 31

Advertising
background image

Maintenance &

Tr

oubleshooting

E-30

Replacing the Projection Lamp

The lamp in this projector operates for approximately 2,000 cumulative hours, depending on the usage environment.
When the lamp has been used for 1,900 hours, the LAMP REPLACEMENT indicator will light red and “LAMP” will
flash in yellow on the screen. It is recommended that the lamp be replaced after 1,900 cumulative hours of use or
when you notice a significant deterioration of the picture and color quality. If the lamp has been used for 2,000 hours,
the projector power will automatically turn off and the projector will enter standby mode. (Refer to “Lamp/Maintenance
Indicators” on page 29.) The lamp usage time can be checked with the On-screen Display (see page 19).
If the new lamp does not light after replacement, take your projector to the nearest Authorized Sharp Industrial LCD
Products Dealer or Service Center for repair. Purchase a replacement lamp unit (lamp/cage module) of the current
type BQC-XGNV4SU/1 from your nearest Authorized Sharp Industrial LCD Products Dealer or Service Center. Then
carefully change the lamp by following the instructions below. If you wish, you may have the lamp replaced at your
nearest Authorized Sharp Industrial LCD Products Dealer or Service Center.

IMPORTANT NOTE TO U.S. CUSTOMERS:

The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of this
projector under warranty, including lamp replacement, must be obtained through an Authorized Sharp Industrial
LCD Products Dealer or Service Center. For the name of the nearest Authorized Sharp Industrial LCD Products
Dealer or Service Center, please call toll-free: 1-800-BE-SHARP (1-800-237-4277).

U.S.A. ONLY

Removing and installing the lamp unit

CAUTION

• Do not remove the lamp cage directly after operation of the projector. The lamp may be extremely hot. Wait at least one

hour after the power cord is disconnected to allow the surface of the lamp cage to fully cool before removing the lamp
cage.

• Be sure to remove the lamp cage by the handle. Be sure not to touch the glass surface of the lamp cage or the inside

of the projector.

• To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.
• Before or after replacing the lamp, be sure to clean the air filters. See page 28 for cleaning the air filters.

4

6

Remove the lamp
cage.

5

Replace the lamp cage
(after changing the lamp).

1

3

Turn off the main
power.

2

Disconnect the power
cord.

Unplug the power cord from the
AC socket.

Slide the lamp cage
cover out.

Slide the lamp cage
cover in.

Slide the lamp cage cover in the
direction of the arrow. Then
fasten the user service screw.

Remove the securing screws
from the lamp cage. Hold the
lamp cage by the handle and
pull it towards you.

Turn over the projector and un-
fasten the user service screw
that secures the lamp cage
cover. Then slide the cover in the
direction of the arrow.

Press

POWER OFF

. After the

cooling fan stops, turn off the

MAIN POWER

switch.

Press the lamp cage firmly into
the lamp cage compartment.
Fasten the securing screws.

Ł

OFF

or

User service
screw

Securing

screw

Securing
screw

User service
screw

XG-NV4SU (E)-e

98.10.19, 5:42 PM

30

Advertising