Motor, Jumpers, Wire "t" moved to 440v terminal – Southbend 6" x 18" SURFACE GRINDER SB1029 User Manual

Page 43

Advertising
background image

For Machines Mfg. Since 8/09

Model SB1029

-41-

E L E C T R I C A L

3.

Without changing the location of any of the

wires, reposition the jumpers as shown in
Figure 54. Stack the jumpers as needed,
since there will be two extras.

Figure 54. 440V Jumper locations.

GND

U

1

2

3

4

5

6

V

W

Motor

7

8

9

Jumpers

4.

Tighten the nine screws that secure the

wires and jumpers, making sure the wires
are still located in their original positions.

5.

Open the electrical box on the side of the

machine. Loosen all of the screws that secure
the wires to the thermal relays and the
screws that secure the thermal relays to the
contactors (Figure 55). Pay careful attention
to the location of the wires so you can replace
them in the same position later.

Figure 55. 220V Thermal relays.

AMP

THERMAL

RELAY

CONTACTOR

Allen Bradley

C09400

1

3

5

7

L1

L2

L3

L4

2

4

6

8

T1

T2

T3

T4

95

96

NO

NC

97

98

AMP

AB 193 TAB60

AB 193 TAB24

THERMAL

RELAY

CONTACTOR

Allen Bradley

C09400

1

3

5

7

L1

L2

L3

L4

2

4

6

8

T1

T2

T3

T4

95

4

5

6

1.6

2.4

96

NO

NC

97

98

8

9

O

O

U

V

W

W1

V1

U1

Figure 56. Wire "T" moved to 440V.

1

2

3

4

5

R

T

Transformer LCP-TBS

For 440V:

Set at 0.25A

For 440V:

"T" Positioned at 440V

0 12 24 0 110

0 208 220 440 480

Wire "T" moved to

440V Terminal

6.

Replace the installed relays for the coolant

pump relay and spindle motor with the
relays from the 440V conversion kit,
installing all of the wires in the same
location from which they were removed.

7.

Move the "T" wire from the 220V terminal
to the 440V terminal on the transformer, as
shown in Figure 56.

8.

Hardwire the machine to a 440V locking

disconnect switch.

READ ELECTRICAL SAFETY

ON PAGE 39 FIRST!