Electrical, Electrical box contents, Fuses 4a transformer lcp-tbs – Southbend 6" x 18" SURFACE GRINDER SB1029 User Manual

Page 55: Ref part # description ref part # description, 440v conversion kit

Advertising
background image

For Machines Mfg. Since 8/09

Model SB1029

-53-

P A R T S

AMP

THERMAL

RELAY

CONTACTOR

Allen Bradley

C09400

1

3

5

7

L1

L2

L3

L4

2

4

6

8

T1

T2

T3

T4

95

96

NO

NC

97

98

AMP

THERMAL

RELAY

CONTACTOR

Allen Bradley

C09400

1

3

5

7

L1

L2

L3

L4

2

4

6

8

T1

T2

T3

T4

95

96

2.4

1.6

0.25

0.1

0.32

NO

NC

97

98

1

2

3

4

5

1

2

3

4

5

T

S

R

U1

W

V

U

0

7

6

4

3

2

R1

T1

1

GND

Fuses

4A

Transformer LCP-TBS

0 12 24 0 110

0 208 220 440 480

Electrical
Box Contents

W1

V1

U1

AB 193 TAB60

AMP

THERMAL

RELAY

440V CONVERSION KIT

95

96

2.4

1.6

NO

NC

97

98

AB 193 TAB60

AB 193 TAB24

501

502

503

504

510

505

506

507

508

509

AMP

THERMAL

RELAY

95

96

NO

NC

97

98

0.25

0.1

0.32

AB 193 TAB24

REF PART #

DESCRIPTION

REF

PART #

DESCRIPTION

501

PSB1029501

TRANSFORMER LCP-TBS 0–480V

506

PSB1029506

FUSE HOLDER

502

PSB1029502

CONTACTOR AB C09400 24V

507

PSB1029507

FUSE 4A

503

PSB1029502

CONTACTOR AB C09400 24V

508

PSB1029508

TERMINAL BLOCK 18P

504

PSB1029504

THERMAL RELAY AB 193 TAB60 1.6–2.4A

509

PSB1029509

GROUNDING BLOCK

505

PSB1029505

THERMAL RELAY AB 193 TAB24 0.1–0.32A

510

PSB1029510

440V CONVERSION KIT FOR SB1029

Electrical

Advertising