43

Cooling

Thermo. ON : When the room temperature rises above T + 4°F (T°F is set temperature).

Compressor

ON

Thermo. OFF : When the room temperature falls below set temperature T°F.

Compressor

OFF

Heating

Heater ON :

When the room temperature falls below T – 4°F (T°F is set temperature).
Heater

ON

Heater OFF :

When the room temperature rises above set temperature T°F.
Heater

OFF

T

°

F

T–4

°

F

set temp.

Heater

Fan motor

ON

ON

Set speed

Room temp.

OFF

OFF

ON

ON

T

°

F

T+4

°

F

set temp.

Compressor

Fan motor

Set speed

Room temp.

OFF

OFF

OFF

Cooling & Electric Heating Model

Models STB0811C1 STB1023C1 STB1123C1