Sony CDX-605 User Manual

Page 7

Advertising
background image

– 34 –

7-8.

IC PIN FUNCTION DESCRIPTION

MAIN BOARD IC302 CXP84124-078Q (SYSTEM CONTROLLER)

Pin No.

Pin Name

I/O

Function

1

LIM.SW

I

Sled limit in detect switch (SW1) input terminal
“L”: When the optical pick-up is inner position

2

BUSON

I

Bus on/off control signal input from the SONY bus interface (IC204) “H”: bus on

3

EJECT

I

Eject switch (SW303) input terminal “H” active

4

LOAD1

I

Save end detect switch (SW12) input terminal
“L”: When completion of the disc chucking operation

5

LOAD2

I

Chucking end detect switch (SW11) input terminal
“L”: When completion of the disc chucking operation

6

A.MUTE

O

Audio line muting on/off control signal output terminal “H”: muting on

7

EMPH

O

Emphasis mode output to the D/A converter (IC401) “L”: emphasis on

8

CH.R

O

Motor drive signal (save direction) output to the chucking motor drive (IC52)
“H” active *1

9

CH.F

O

Motor drive signal (load chucking direction) output to the chucking motor drive (IC52)
“H” active *1

10

O

Not used (open)

11

ELV.R

O

Motor drive signal (elevator down direction) output to the elevator motor drive (IC301)
“L” active *2

12

ELV.ON

O

Mechanism deck section power supply on/off control signal output “H”: power on

13

CD RST

O

System reset signal output to the CXA1992AR (IC11), CXD2530Q (IC101) and SM5852FS
(IC102) “L”: reset

14

CDON

O

D/A converter and servo section power supply on/off control signal output “H”: power on

15 to 23

O

Not used (open)

24

AUTO ON/OFF

I

Setting terminal for the automatic adjustment “L”: automatic adjustment, “H”: manual
adjustement (solder across the BP302 terminal) Normally: fixed at “L”

25 to 29

O

Not used (open)

30

RESET

I

System reset signal input from the reset signal generator (IC202) and SONY bus interface
(IC204) “L”: reset
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”

31

EXTAL

I

Main system clock input terminal (8 MHz)

32

XTAL

O

Main system clock output terminal (8 MHz)

33

VSS

Ground terminal

34

TX

O

Sub system clock output terminal Not used (open)

35

TEX

I

Sub system clock input terminal Not used (fixed at “L”)

36

AVSS

Ground terminal (for A/D converter)

37

AVREF

I

Reference voltage (+5V) input terminal (for A/D converter)

38

ATRIBT

I

Selection input of the custom file, D-BASS, etc.

39

MCK

I

Input of signal for the fine adjustment (linear position sensor adjustment; RV301) of elevator
position (A/D input)

40

EHS

I

Elevator height position detect input from the RV302 (elevator height sensor) (A/D input)

41

H.TEMP

I

High temperature sensor input terminal Not used (open)

42

O

Not used (open)

43

MODE1

O

D-BASS control signal output to the SM5852FS (IC102)

44

MODE2

O

D-BASS control signal output to the SM5852FS (IC102)

45

MODE3

O

D-BASS control signal output Not used (open)

46, 47

O

Not used (open)

48

SCK

I

Serial data transfer clock signal input from the SONY bus interface (IC204)

49

SI

I

Serial data input from the SONY bus interface (IC204)

Advertising