Information about software, Xcp issues and workarounds – Siemens SPARC ENTERPRISE M8000 User Manual
Page 16
8
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1072 • September 2008
Information about Software
This section describes the special instructions and the issues about the SPARC 
Enterprise M8000/M9000 servers software.
■
■
Solaris OS Issues and Workarounds
■
Software Documentation Updates
■
Identifying Degraded Memory in a System
■
Identifying Different Memory Sizes in a System Board
■
Identifying Permanent Memory in a Target Board
■
XCP Issues and Workarounds
lists known XCP issues and possible workarounds.
TABLE 3
XCP Issues and Workarounds
ID
Description
Workaround
RTIF1-
070418-009
While XSCF is running, a process may go 
down, a watchdog timeout may occur, or a 
hang-up may occur. After this, XSCF may 
reset. 
Check that XSCF is started.
to be translated.
If
not started, stop all the domains and then 
execute the system power off/on (AC 
OFF/ON). To turn on the system power that 
you turned off, wait at least 30 seconds before 
power-on.
RTIF1-
070528-002
While XSCF is running, watchdog timeout 
may occur and XSCF may reboot.
Check that XSCF is started. If not started, stop 
all the domains and then execute the system 
power off/on (AC OFF/ON). To turn on the 
system power that you turned off, wait at least 
30 seconds before power-on.