Siemens SPARC ENTERPRISE M8000 User Manual
Page 19
Information
about
Software
11
RTIF1-
080512-001
When you specify "localhost" to the 
hostname of the sethostname(8) command 
and reset XSCF by using the 
applynetwork
(8) and the rebootxscf(8)
commands, a process goes down in XSCF.
Do not specify "localhost" to the hostname of 
the sethostname(8) command.
RTIF1-
080526-001
When the system is stressed with many faults, 
the fmd process on the service processor might 
hang. Once this happens, fma commands on 
the service processor can fail or hang.
Reboot the service processor using the XSCF 
command rebootxscf(8).
RTIF1-
080725-001
In setsnmp addv3traphost, when the 
authentication failed due to the reasons such 
as the trap host not working, or the wrong 
user name or password, the subsequent SNMP 
traps will not be notified. 
There is no workaround. 
Confirm that the SNMP trap host is working 
and re-execute the setsnmp(8) command 
using the correct user name.
RTIF1-
080725-002
When the SNMPv3 trap has been set, after the 
watchdog timeout occurred in XSCF and XSCF 
reset, the subsequent SNMP traps will not be 
notified.
There is no workaround.
RTIF1-
080725-003
The initial value that set with the 
setdomparam
set-defaults option differs
from the initial value of OpenBoot PROM. 
parameters current value expected value 
diag-level
none(0x00) min(0x20)
auto-boot?
false(0x00) true(0xff)
In the OpenBoot PROM prompt (ok>), execute 
the set-defaults command to restore the 
OpenBootPROM environmental variables to 
the initial value. 
RTIF1-
080725-004
After set the Daylight Saving Time by using 
the XSCF shell, XSCF Web does not show the 
correct time in the Logs menu.
There is no workaround.
Use the showlogs(8) command of the XSCF 
shell.
RTIF1-
080808-001
On the cluster system using the 
PRIMECLUSTER software, when there are 10 
or more RCI units, the RCI busy status may be 
temporarily unreleased and output the 
following syslog message:
SA_pprcir.so to test host
host_name
failed
Refer to the manual of the PRIMECLUSTER 
software to check the cluster status. If no 
problem found on the status, this message can 
be safely ignored. If any problem, follow the 
instructions on the manual to solve the 
problem.
TABLE 3
XCP Issues and Workarounds (Continued)
ID
Description
Workaround