24
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1072 • September 2008
6614737
The DR deleteboard(8) and moveboard(8) 
operations might hang if any of the following
conditions exist:
• A DIMM has been degraded.
• The domain contains system boards with 
different memory size.
This has been fixed in patch 137111-01.
[Workaround]
Avoid performing DR operations if any of the 
listed conditions exist.
To determine whether the system contains 
degraded memory, use the XSCF 
showstatus
(8) command. For sample output,
see
“Identifying Degraded Memory in a
To determine whether the domain contains 
system boards with different memory sizes, 
display the list of memory sizes using the 
XSCF showdevices(8) command or the 
prtdiag
(8) command on the domain. For
sammple of output, see
Memory Sizes in a System Board” on page 29
If a DR command hangs, reboot the domain to 
recover. 
6619224
For Solaris domains that include SPARC 64 VII 
processors, a single domain of 256 threads (128 
cores) or more might hang for an extended 
period of time under certain unusual 
situations. Upon recovery, the uptime 
command will show extremely high load 
averages. 
This has been fixed in patch 137111-03.
[Workaround]
For Solaris domains that include SPARC 64 VII 
processors, do not exceed a domain size of 256 
virtual CPUs in a single Solaris domain. This 
means a maximum of 32 CPU chips in a single 
domain configuration (maximum 
configuration for an M8000 server). 
6623226
The Solaris command lockstat(1M) or the 
dtrace lockstat provider might cause a system 
panic. 
Do not use the Solaris lockstat(1M) 
command or the dtrace lockstat provider. 
6625734
Systems with large number of processors in a 
single domain environment may have 
suboptimal performance with certain 
workloads.
Use processor sets to bind application 
processes or LWPs to groups of processors. 
Refer to the psrset(1M) man page for more 
information.
TABLE 4
Solaris OS Issues and Workarounds (Continued)
CR ID
Description
Workaround