Connecting the cables to the outdoor unit, As12a5(a6)mc, As18a5(a6)rc – Samsung AS07A5(A6)MA User Manual

Page 37

Advertising
background image

E-

37

ENGLISH

I

NSTALLING THE

O

UTDOOR

U

NIT

Connecting the Cables to the Outdoor Unit

One electric cable must be connected to the outdoor unit:

◆ The assembly cable connecting the indoor unit to the outdoor unit

1

Remove the terminal board cover on the side of the outdoor unit.

2

Connect the assembly cable to terminals as shown in the figure.

➢

Each wire is labelled with the corresponding terminal number.

➢

Each wire from the terminal number of the indoor unit.

Shall be comected with the same terminal number of its
outdoor unit.

3

Connect the earth wires to the earth terminals.

➢

Refer to the page 39 for further details on how to check

that earthing is correct.

4

Replace the terminal board cover, carefully tightening the screw.

✴✴

07/09

✴✴

AS12A5(A6)MC

✴✴

18/24

✴✴

AS12AA(AB)MC

N

L

1

2

3

N1 1

2

3

N

L

1

L

N

E

L

1

E

N

E

L

E

N

Indoor
unit

Outdoor
unit

Earth
terminal

Circuit Breaker(Main Power)

AS12A5(A6)MC

A

B

1

2

3

4

L1 L2

A

B

1

2

3

4

2

1

E

2

1

E

E

E

A

B

A

B

L2

L1

Indoor
unit

Outdoor
unit

Earth
terminal

Circuit Breaker(Main Power)

AS18A5(A6)RC

A

B

1

2

3

4

L1 L2

A

B

1

2

3

4

3

2

1

E

3

2

1

E

E

E

L1

L2

A

B

A

B

Indoor
unit

Outdoor
unit

Earth
terminal

Circuit Breaker(Main Power)

AS18A9(A0)RCD / AS24A1(A2)RC

L1 L2

1

2

3

(A) 1

L1 L2

1

E

L2

1

E

L1

L2

L1

E

E

L2

L1

Indoor
unit

Outdoor
unit

Earth
terminal

Circuit Breaker(Main Power)

✴✴

07/09

✴✴

/ AS12AA(AB)MC

Advertising