Auxiliary circuit breaker electrical work – Samsung AS07A5(A6)MA User Manual

Page 38

Advertising
background image

E-

38

I

NSTALLING THE

O

UTDOOR

U

NIT

Auxiliary Circuit Breaker

Electrical Work

1

The supply voltage must be the same as the rated voltage of the
air conditioner.

2

Prepare the power souce for exclusive use with the air conditioner.

3

Use 15 amperes time delay fuse or circuit breaker.

➢

When using the special NFB, use the NFB to bear the capacity of the
air conditioner.

➢

Otherwise, the shot circuit in the NFB may occur.

Outdoor unit

Distribution

board

Auxiliary

power s/w

◆ Auxiliary circuit breaker should be installed near outdoor unit so

that each access is possible. Main/outdoor power supply cable are
connected to upper/lower terminal of auxiliary circuit breaker.

◆ It is necessary that the conduit kit for power supply to the outdoor

unit be installed between auxiliary power S/W and the outdoor
unit. (the conduit kit is optional)

❊

The designs and shape are subject to

change according to the model.

MODEL

AS09A5(A6)MA

AS12A5(A6)MC

Power supply

Power cable

Assembly cable

Operating current(C)

Starting Current

Power consumption (C)

115V~/60Hz

Single phase

AS07A5(A6)MA

115V~/60Hz

Single phase

3G AWG 14

4G AWG 16

31A

1320W

47A

32A

6.4

8.5

6.1

900W

680W

208-230V~/60Hz

Single phase

MODEL

AS18A5(A6)RC AS18A9(A0)RCD AS24A1(A2)RC

Power supply

Power cable

Assembly cable

Operating current(C)

Starting Current

Power consumption (C)

208-230V~/60Hz

Single phase

AS12AA(AB)MC

208-230V~/60Hz

Single phase

3G AWG 14

4G AWG 16

5G AWG 16

6G AWG 16

10.5A

10.5A

2350W

35A

37A

8.6A

8.0A

31A

5.4

1900W

1770W

1230W

208-230V~/60Hz

Single phase

208-230V~/60Hz

Single phase

Advertising