Auxiliary Circuit Breaker

Electrical Work

1

The supply voltage must be the same as the rated voltage of the
air conditioner.

2

Prepare the power souce for exclusive use with the air conditioner.

3

Use 15 amperes time delay fuse or circuit breaker.

When using the special NFB, use the NFB to bear the capacity of the
air conditioner.

Otherwise, the shot circuit in the NFB may occur.

Outdoor unit

Distribution

board

Auxiliary

power s/w

Auxiliary circuit breaker should be installed near outdoor unit so

that each access is possible. Main/outdoor power supply cable are
connected to upper/lower terminal of auxiliary circuit breaker.

It is necessary that the conduit kit for power supply to the outdoor

unit be installed between auxiliary power S/W and the outdoor
unit. (the conduit kit is optional)

The designs and shape are subject to

change according to the model.

MODEL

AS09A5(A6)MA

AS12A5(A6)MC

Power supply

Power cable

Assembly cable

Operating current(C)

Starting Current

Power consumption (C)

115V~/60Hz

Single phase

AS07A5(A6)MA

115V~/60Hz

Single phase

3G AWG 14

4G AWG 16

31A

1320W

47A

32A

6.4

8.5

6.1

900W

680W

208-230V~/60Hz

Single phase

MODEL

AS18A5(A6)RC AS18A9(A0)RCD AS24A1(A2)RC

Power supply

Power cable

Assembly cable

Operating current(C)

Starting Current

Power consumption (C)

208-230V~/60Hz

Single phase

AS12AA(AB)MC

208-230V~/60Hz

Single phase

3G AWG 14

4G AWG 16

5G AWG 16

6G AWG 16

10.5A

10.5A

2350W

35A

37A

8.6A

8.0A

31A

5.4

1900W

1770W

1230W

208-230V~/60Hz

Single phase

208-230V~/60Hz

Single phase

Advertising