Xli replies, Xli responds, F73<s>threshold<cr – Symmetricom XLi IEEE 1588 User Manual
Page 84: F73<s>threshold<s><nanoseconds><s>ns<cr><lf, Nanoseconds, F73<s>threshold<sep><nanoseconds><cr, Ok<cr><lf, F73<s>timeout<cr, F73<s>timeout<sep><seconds><s>s<cr><lf, F73<s>timeout<sep><seconds><cr

76
XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
1
To view the Time Threshold setting, enter:
F73<S>THRESHOLD<CR>
XLi replies:
F73<S>THRESHOLD<S><nanoseconds><S>ns<CR><LF>
where <nanoseconds> is the time error threshold in ns
To set a new Time Threshold, enter a new value for
<nanoseconds>
(Range 0 to 99,999 ns), as follows:
F73<S>THRESHOLD<SEP><nanoseconds><CR>
XLi replies:
OK<CR><LF>
To view Timeout Delay, enter:
F73<S>TIMEOUT<CR>
XLi replies:
F73<S>TIMEOUT<SEP><seconds><S>s<CR><LF>
To enter a new Time Delay, enter a value for <seconds> (Range 0 to 86,400 ns), as follows:
F73<S>TIMEOUT<SEP><seconds><CR>
XLi replies:
OK<CR><LF>
To enable LED Blink, enter:
F73<S>BLINK<SEP> ENABLE<CR>
XLi responds:
OK<CR><LF>
To disable LED Blink, enter:
F73<S>BLINK<SEP> DISABLE<CR>
To view the Power-On Alarm Suppress setting, enter:
F73<S>SUPPRESS<CR>