STANDARD PROGRAMMING

You hear a long beep. The arm light and the red lights in zones 3 and 4 go on.
Both the green and red lights flash in zone 1 for 45 seconds which gives you 45
seconds to leave the premises before the system is activated. After 45 seconds,
both the green and red lights in zone 1 remain on. Upon re-entering the premises
through zone 1, you have 30 seconds till the alarm sounds. The system gives
you 30 seconds from the time you activate the door/window sensor, for example
opening the front door, to get to the Control Panel to deactivate the system. Zone
2 remains off which allows the person in the premises to move around without
activating the motion sensor. Zones 3 and 4 remain instant. If any sensor in zone
3 or 4 are activated, the alarm sounds instantly.

Option 3: Night Sequence - To arm your system when there are people in the
premises and no one is expected to enter or exit
. Example at night when every-
one is sleeping.

1. Press the current MPIN [ 0 0 0 ].

2. Press [ A ].

3. Press [ B ].

You hear a long beep. The arm light, the red light in zones 1, 3 & 4 go on. If any of
the sensors are activated in any of these 3 zones, the alarm is sounded instantly.
Zone 2, the motion sensor, remains off allowing movement throughout the premises.

TO DISARM THE SYSTEM USING THE KEYPAD ON THE CONTROL PANEL

1. Press the current MPIN [ 0 0 0 ].

2. Press [ # ].

All the lights but the AC PWR light go off. The system is now disarmed.

Note: If [MPIN,#] is entered when the system in not activated, the system will
default back to the last sequence before the unit was turned off.

Emergency Silent Alarm works in conjunction with the Emergency Dialer AD-433S
(option), see Additional Accessories.

If under duress when disarming the system:

1. Enter the current MPIN [ 0 0 0 ].

2. Press [ B ] [ B ].

This will terminate the delay mode (stop the steady repeated beep) and return to
the previous arm mode. It will also send a signal to the Emergency Dialer silently
which will then automatically send a prerecorded message for help.

Note: Do not use Emergency Silent Alarm [PIN], [B], [B] if your Skylink security
system includes the Audio alarm AA-433, since the Silent alarm is not designed
to work with AA-433, which means [PIN], [B], [B] will sound the siren of the AA-433
instantly.

TO ARM SYSTEM USING THE KEYCHAIN TRANSMITTER

There are 2 different arm options to choose from:

1. Press button #1, and the Control Panel will beep once.

The system will be armed in the Away Sequence. To be used to arm the system
when you are the last person leaving the premises. (see page 12 for informa-
tion on the Away Sequence).

Pressing button #1 will give you the same result as pressing:
MPIN, [ B ] , [ C ] on the keypad.

2. Press button #2, and the Control Panel will beep once.

The system will be armed in Home Sequence. To be used to arm the system
when someone remains in the premises. (see page 12 for information on
the Home Sequence).

Pressing button #2 will give you the same result as pressing: MPIN, [ C ] on the
keypad.

The Keychain Transmitter conveniently fits on any keychain. It allows you to arm
and disarm the system from a distance of approximately 100 feet from the Control
Panel. The distance will depend on what is between the keychain transmitter and
the Control Panel. It also has a panic button that lets you remotely activate the
siren instantly.

Note: Make sure you press down on the transmitter for one full second or the
system may not respond.

14

PANIC

2

1

3

KEYCHAIN TRANSMITTER (4B-434)

Advertising