RS-232

COMMUNICATION

Appendix E

RS-232 communication

RS-232C communication

Connect the computer and projector while both are off and make sure the projector is
turned on first. The connector scheme (from left to right) is:

• top (pin 9,8,7,6): not used, not used, not used, not used
• bottom (pins 5,4,3,2,1) : ground, not used, receive data, send data, not used.

RS-232C jack D-sub 9-pin

Communications setting

1.Command data

Command data (3) + Setting value (2).

2.Requesting projector status (Read command)

3.Changing the projector settings (Write command)

Computer (Windows) - HyPer Terminal
Command Or Read command

In Hyper Terminal, Press Enter Key
(Ex.BRI 20 Sets the brightness to 20)

RS-232 Port Settings

Setting

Value

bits per second

57600

Data bits

8

Parity

None

Stop bits

1

Flow control

None

RS-232 Port Settings

Function

Command

Response

Brightness

(BRI ??)

(0-99)

Contrast

(CON ??)

(0-99)

Write Command Examples

Function

Command

Response

Brightness

(BRI 10)

Brightness Write OK

Contrast

(CON 10)

Contrast Write OK