<Item name = "system-description">Siemens Communications</Item>
<!-- The DNS domain name, e.g. ust.local
-->
<Item name = "dns-domain-name">ust.local</Item>
<!-- The default and second DNS server IP address
-->
<Item name = "dns-server-addr">172.16.127.2</Item>
<Item name = "dns-server-addr2">172.16.127.3</Item>
<!-- Describes the LAN port operation mode (0 = auto, 1 = 10 Mbps, 2 = 100 Mbps) -->
<Item name = "port1">0</Item>
<Item name = "port2">0</Item>
<!-- Registration time (in seconds) before reregistration is necessary, e.g. 3600
-->
<Item name = "reg-ttl">3600</Item>
<!-- Registrar IP address or domain name
-->
<Item name = "registrar-addr">as.broadworks.net</Item>
<!-- SIP server IP address or domain name
-->
<Item name = "reg-addr">as.broadworks.net</Item>
<!-- SIP server type (1=HiQ8000, 2=BroadSoft, 3=Sylantro, 4=other
-->
<Item name = "server-type">2</Item>
<!-- Session timer enabled (true or false)
-->
<Item name = "session-timer">false</Item>
<!-- Session duration e.g. 3600
-->
<Item name = "session-duration">3600</Item>
<!-- Gateway IP address (if used)
-->
<Item name = "sgnl-gateway-addr">0.0.0.0</Item>
<!-- Routing type (0 = server router, 2 = gateway routed)
-->
<Item name = "sgnl-route">0</Item>
<!-- Transport protocol, (0 = UDP, 1 = TCP, 2 = TLS)
-->
<Item name = "sip-transport">0</Item>
-<!-- Outbound proxy (true/false)
-->
<Item name = "outbound-proxy">true</Item>
<!-- Default outbound proxy domain
-->
<Item name = "default-domain">as.broadworks.net</Item>
<!-- Country setting, (0 = US, 1 = UK, 2 = DE, 3 = FR, 4 = IT, 5 = ES, 6 = AT,
-->
<!-- 7= CH, 8=BE)
-->
Element or description