19 sip session timer value, 20 registration timer value, 21 sip realm – Siemens OPTIPOINT 410 S V6.0 User Manual

Page 38

Advertising
background image

xml_03.fm

A31003-J4260-M101-2-76A9, 03-2007
XML Configuration Management, Administrator Manual

3-15

XML Overview

Administration Tags

3.3.3.19

SIP session timer value

3.3.3.20

Registration timer value

3.3.3.21

SIP realm

Parameter

session-duration

WEB

Index

Value

1 to 3600

Session duration in seconds;
default: 3600

Example

<Item name="session-duration">3600</Item>

Notes

e164

Parameter

reg-ttl

WEB

Index

Value

1 to 3600

Registration time (in seconds) be-
fore reregistration is necessary;
default: 3600

Example

<Item name="regttl">3600</Item>

Notes

e164

Parameter

realm

WEB

Index

Value

ABCDabcd1234

String (max. 93; Alphanumeric)

Example

<Item name="realm">as.broadworks.net</Item>

Notes

e164

Advertising