Schumacher 00-99-000886 User Manual

Page 11

Advertising
background image

8

DESULFATION MODE:

11.5

If a battery is left discharged for an extended

period of time, it could become sulfated and not accept a normal charge.

The CHARGING LED will blink when the special desulfation mode is ac-

tivated. When blinking, the charger has switched to the Desulfation Mode

of operation. If successful, normal charging will resume after the battery is

desulfated. The CHARGING LED will then stop blinking and light continu-

ously. Desulfation could take up to 10 hours. If desulfation fails, charging

will abort and the CONNECTED LED will remain lit and the display will

read BAD BAT.
COMPLETION OF CHARGING:

11.6

Charge completion is indicated by the

CHARGED LED. When lit, the charger has stopped charging and has

switched to Maintain Mode of operation.
MAINTAIN MODE:

11.7

When the CHARGED LED is lit, the charger has

started Maintain Mode. This mode of operation is known as Float-Mode

Monitoring. In this mode, the charger keeps the battery fully charged by

delivering a small current, when necessary. The voltage is maintained at a

level determined by the BATTERY TYPE selected. To finish the charging

cycle press the START/STOP button, and the OFF LED will light.
GENERAL CHARGING NOTES:

11.8

The fan runs whenever one or more batteries are being charged.
If the charge mode is changed after charging has started (by pressing the

BATTERY TYPE button), the charging process stops.
The voltage displayed during charging, is the charging voltage and usually

will be higher than the battery’s resting voltage.

USING THE vOLT METER TO TEST BATTERy STATE OF CHARGE

12.

OvERvIEW

12.1

The charger has a built in volt meter to test your battery’s state of charge.

The charger does not have a built in load tester. As such, a recently

charged battery could have a temporarily high voltage due to what is

known as “surface charge”. The voltage of such a battery will eventually

drop during the period immediately after the charging system is disen-

gaged. Consequently, the tester could display inconsistent values for such

a battery. For a more accurate reading, the surface charge should be

removed by temporarily creating a load on the battery by turning on the

lights or other accessories.
The battery tester is only designed to test 12V batteries. Testing a device

with a rapidly changing voltage could yield unexpected or inaccurate

results.
TESTING SEQUENCE:

12.2

There are three basic steps required to test the

battery state of charge:

Connect the battery charger’s clips to the battery. Be sure to follow all

1.

of the precautions listed under sections 6 and 7.

Advertising
This manual is related to the following products: