Connect the L1 of the power supply to the black wire, the
L2 or neutral lead to the red wire, and the ground wire to
the green wire (See Figure 23).
A time clock controlling the filter pump should have a low-
voltage Fireman’s Switch that switches off the heater at
least 15 minutes before shutting off the pump.

FIREMAN’S SWITCH CONNECTION

NOTICE: If, while there is line voltage connected to the
heater, you touch either line voltage terminal with any
24VAC wire that is connected to the control board (includ-
ing the Fireman’s Switch jumper), you will immediately
destroy the control board and void the warranty.

NOTICE: When using a timer and Fireman’s Switch, the
heater’s power supply should come from the load side of
the timer. The Fireman’s Switch completes the circuit for
the low voltage safety switches. It DOES NOT get any line
voltage power from the power supply.
Connect the Fireman’s switch to the heater as follows:
1. Turn off power to heater at main circuit breaker panel.
2. Unbolt and remove the upper jacket halves (see Figure

3, Page 5).

3. Open control box cover (see Figure 24).
4. Remove the factory-installed jumper between the

Fireman’s Switch terminals (see Figure 25).

5. Connect the wires between the Fireman’s Switch termi-

nals on the heater and those on the time clock using
18 gauge wire with a minimum 3/64” (1.2mm) thick
insulation rated for a temperature rise of at least
105°C. Route the wires out through the knockout on
the bottom of the Control Box. Use a 90° conduit el
and conduit run out through the cutout on the Lower
Enclosure, next to the Junction Box (see Figure 23).

21

Wire into bottom
of Junction-box
in Flexible Conduit

Wiring Harness
to Control Box

120/240V: Black
to Black (L1)

120V: White to Red (L2) or
240V: Red to Red (L2)

Green (Ground)

to

Green (Ground)

Bonding Wire

Bonding
Wire

Bonding Lug

View From Below
(Exterior)

View From Above
(Interior)

Cutout for
Conduit from
Fireman's Switch

PR

ES

S

TA

B

VE

NT

PIL

OT

O

F

F

OFF

O

N

ON

GND

L1

GROUND (GND)

L2

JUNCTION

BOX

L1

L2

BM

FL

F1

L1

TRANS

F

I

R
E
M
A
N
S

S

W

I

T
C
H

Fireman’s Switch
Completes the heater
24 Volt AC Control
Board Circuit.
DO NOT connect this
circuit to Line Voltage!

Y Y

R

W

G

Y

Y

TERMINAL BOARD

TRANS

TRANS

FUSE

FUSE

L2

Time Clock or Remote

(Purchase Separately —

Supplies Power to

Circulator Pump)

24VAC

24VAC

BK

O

O

BK

W

R

BK

R

W

12 Pin

Receptacle

VA

L

TH

IND

GND

24V

AC

24V

AC

FS

THERMIST

OR

OPERATING CONTROL

DISABLE TOGGLE

ENABLE TOGGLE

CONTROL CENTER

SPA CONTROL

VERSION 1 PAD

MEMBRANE PAD

CONNECTION

9

1

J6

FIGURE 24: Open Control Box Cover

FIGURE 25: Fireman’s Switch Connections

FIGURE 23: Field Wiring

Advertising
This manual is related to the following products: