2-28

(3)

Head position adjustment

Adjusts the head position for the scanning direction on a Bk head
basis.
Enter an adjustment value according to the head adjustment pattern.

1

Select "ADJUST", and then press the

key to display

"H-POS ADJ".

2

Press the

key to display the head to be adjusted, and

press the

key.

3

Of the main scan head position adjustment of the "HEAD

ADJ1" patterns, enter a numeric value of the fittest

pattern.

Select the digit to be entered between > and & with

,

keys, and change value with

,

keys.

4

Press the

key.

# H-POS ADJ Lm

> +00&A

# H-POS ADJ Lc

> +00&A

-21

+2

Find a head adjustment sample where
the BK head-line and the head-position

are aligned. In case of LC-head
illustrated in the right, for instance, -21

shows the sample where both are not
aligned; +2 shows the sample where

both are aligned. Accordingly, input + 2
as an appropriate adjustment value.