Model 4501-XX Toxic Gas Sensor Module

Page 16 of 35

Figure 7 - 1: Module Components

7. SERVICE

7.1 SENSOR MODULE CONFIGURATION

The gas sensor module is comprised of the following sub-assemblies (Figure 7-1):

4501-XX

Gas Sensor Module

SPL27077

Stainless Steel Enclosure (SPL 27085 for Aluminum Enclosure)

SPM27071 Transmitter

Assembly

XXXXXXX

Sensor Assembly (see Appendix B)

XXXXXXX

Sensor (see Appendix B)

There are no field serviceable components below the sub assembly level.

NOTE

Area must be determined to be non-hazardous before opening enclosure.

7.2 ENCLOSURE REPLACEMENT

The enclosure should be replaced if the cover threads or conduit threads have been damaged, or if the
enclosure has been damaged sufficiently that it no longer meets the required NEMA classification.

To replace the enclosure follow the transmitter and sensor assembly removal instructions, remove the
damaged enclosure from its conduit, install a new enclosure and continue the transmitter and sensor assembly
replacement instructions.