Calibration procedure, Adjusting the speed sensor, Maintenance menu – Sole Control Remotes TT8 User Manual

Page 23

Advertising
background image

TT8

-22-

Calibration procedure:

1) Remove the safety key
2) Press and hold down the Start and Fast (speed up) buttons with one hand and replace the safety key

with the other. Continue to hold the Start and Fast key until the window displays Factory settings , then
press the enter key.

3) You will now be able to set the display to show Metric or English settings. To do this press the up or

down key to show which you want, then press enter.

4) Make sure the wheel size diameter is 2.98 then press enter
5) Adjust the minimum speed (if needed) to 0.5 and then press enter
6) Adjust the maximum speed (if needed) to 12.0 and then press enter
7) Adjust the maximum elevation (if needed) to 15 and then press enter
8) Press start to begin calibration. The process is automatic. The speed will start up without warning; so do

not stand on the belt.

Adjusting the speed sensor:

If the calibration does not pass you may need to check the speed sensor alignment.

1) Remove the motor cover hood.
2) The speed sensor is located on the left side of the frame, right next to the front roller pulley (the pulley will

have a belt around it that also goes to the motor). The speed sensor is small and black with a wire
connected to it.

3) Make sure the sensor is as close as possible to the pulley without touching it. You will see a magnet on

the face of the pulley; make sure the sensor is aligned with the magnet. There is a screw that holds the
sensor in place that needs to be loosened to adjust the sensor. Re-tighten the screw when finished.

Maintenance menu:

1) Press and hold the Start, Stop and Enter key at the same time, until the display shows Engineering

mode (it may say maintenance menu, depending on version). Press the Enter key.

2) You can now scroll through the menu using the up and down keys. Use the Stop key to return to previous

menu selection. The menu selections are:

1) Calibration (used to verify calibration)
2) Factory settings (These should not be changed unless instructed by Sole service department)
3) Security (This allows you to lock the console keyboard)
4) Functions

i. Sleep (turns sleep mode on or off)

ii. Pause (turns pause mode on or off)

iii. Maintenance (reset lube message and odometer readings)
iv. Units (set display to English or Metric readings)

v.

Grade

return (returns the elevation to lowest setting when pause is pressed)

5) Display test (lights all LED lights for testing)
6) Key test (tests that all keys are functioning)

Advertising