Sony MDS-PC3 User Manual

Page 31

Advertising
background image

31

KMS

260B

20101
H0576

Iop = 57.6 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (

)

7. Then, rotate the AMS knob and display “LDPWR CHECK”

(C13).

8. Press the @/1 button once and display “LD 0.9 mW $

”.

Check that the reading of the laser power meter become 0.85 to
0.91 mW.

9. Press the @/1 button once more and display “LD 7.0 mW $

”. Check that the reading the laser power meter and digital

volt meter satisfy the specified value.
Note down the digital voltmeter reading value.

Specified Value :

Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading : Optical pick-up displayed value ± 10%

(Optical pick-up label)

10. Press the x/Z button and display “LDPWR CHECK” (C13)

and stop the laser emission.
(The x/Z button is effective at all times to stop the laser
emission.)

11. Rotate the AMS knob to display “Iop Write” (C05).
12. Press the @/1 button. When the display becomes

Ref=@@@.@ (@ is an arbitrary number), press the @/1 button
to display “Measu=@@@.@” (@ is an arbitrary number).

13. The numbers which can be changed will blink. Input Iop value

noted down at step 9.
To select the number : Rotate the AMS knob.
To select the digit : Press the AMS knob

14. When the @/1 button is pressed, “Complete! !” will be dis-

played momentarily. The value will be recorded in the non-vola-
tile memory and the display will become “Iop Write” (C05).

Note 1: After step 4, each time the @/1 button is pressed, the

display will be switched between “LD 0.7 mW $

”, “LD

6.2 mW $

”, and “LD Wp $

”. Nothing needs

to be performed here.

(For details of the method for checking
this value, refer to “5-8. Recording and
Displaying Iop Information”.)

5-12. TRAVERSE ADJUSTMENT

Connection :

Adjusting Procedure :
1. Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin

6

(VC) of the BD board.

2. Load a test disc (MDW-74/GA-1). (Refer to Note 1.)
3. Rotate the AMS knob and display “EF MO ADJUST” (C07).
4. Press the @/1 button and display “EFB =

MO-R”.

(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)

5. Rotate the AMS knob so that the waveform of the oscilloscope

becomes the specified value.
(When the AMS knob is rotated, the

of “EFB=

” changes

and the waveform changes.) In this adjustment, waveform var-
ies at intervals of approx. 2%. Adjust the waveform so that the
specified value is satisfied as much as possible.
(Read power traverse adjustment)

(Traverse Waveform)

6. Press the @/1 button and save the result of adjustment to the

non-volatile memory (“EFB =

SAVE” will be displayed for a

moment. Then “EFB =

MO-W” will be displayed).

7. Rotate the AMS knob so that the waveform of the oscilloscope

becomes the specified value.
(When the AMS knob is rotated, the

of “EFB-

MO-W”

changes and the waveform changes.) In this adjustment, wave-
form varies at intervals of approx. 2%. Adjust the waveform so
that the specified value is satisfied as much as possible.
(Write power traverse adjustment)

(Traverse Waveform)

8. Press the @/1 button, and save the adjustment results in the

non-volatile memory. (“EFB =

SAVE” will be displayed for

a moment.)

9. “EFB =

MO-P”. will be displayed.

The optical pick-up moves to the pit area automatically and servo
is imposed.

V : 0.5 V/div
H : 10 ms/div
Input : DC mode

Oscilloscope

BD board

CN105 pin

4

(TE)

CN105 pin

6

(VC)

VC

A

B

Specification A = B

VC

A

B

Specification A = B

R

5-11. Iop NV SAVE

Write the reference values in the nonvolatile memory to perform
“Iop Compare”. As this involves rewriting the reference values, do
not perform this procedure except when adjusting the laser power
during replacement of the optical pick-up and when replacing the
IC102. Otherwise the optical pick-up check may deteriorate.

Note: Perform this function with the optical pick-up set at room

temperature.

Procedure
1. Rotate the AMS knob to display “Iop NV Save” (C06).
2. Press the @/1 button and display “Iop [stop]”.
3. After the display changes to “Iop =xxsave?”, press the @/1

button.

4. After “Complete!” is displayed momentarily, the display changes

to “Iop 7.0 mW”.

5. After the display changes to “Iop=yysave?”, press the @/1

button.

6. When “Complete!” is displayed, it means that Iop NV saving

has been completed.

Advertising