Sony MDS-PC3 User Manual

Page 33

Advertising
background image

33

5-14. ERROR RATE CHECK

5-14-1. CD Error Rate Check

Checking Procedure :
1. Load a check disc (MD) TDYS-1.
2. Rotate the AMS knob and display “CPLAY1MODE” (C34).
3. Press the @/1 button twice and display “CPLAY1 MID”.
4. The display changes to “C =

AD =

)”.

5. Check that the C1 error rate is below 20.
6. Press the x/Z button, stop playback, press the x/Z “PGM”

button, and remove the test disc.

5-14-2. MO Error Rate Check

Checking Procedure :
1. Load a continuously recorded test disc (MDW-74/GA-1).

(Refer to “5-5. Using the Continuously Recorded Disc”.)

2. Rotate the AMS knob and display “CPLAY1MODE” (C34).
3. Press the @/1 button and display “CPLAY1 MID”.
4. The display changes to “C =

AD =

)”.

5. If the C1 error rate is below 20, check that ADER is 00.
6. Press the x/Z button, stop playback, press the x/Z “PGM”

button, and remove the test disc.

5-15. FOCUS BIAS CHECK

Change the focus bias and check the focus tolerance amount.
Checking Procedure :
1. Load a continuously recorded test disc (MDW-74/GA-1).

(Refer to “5-5. Using the Continuously Recorded Disc”.)

2. Rotate the AMS knob and display “CPLAY1MODE” (C34).
3. Press the @/1 button twice and display “CPLAY1 MID”.
4. Press the x/Z button when “C =

AD =

)” is dis-

played.

5. Rotate the AMS knob and display “FBIAS CHECK” (C16).
6. Press the @/1 button and display “

/

c =

”.

The first four digits indicate the C error rate, the two digits after
[/] indicate ADR, and the 2 digits after [c =] indicate the focus
bias value.
Check that the C error is below 20 and ADER is below 2.

7. Press the @/1 button and display “

/

b =

”.

Check that the C error is below 100 and ADER is below 2.

8. Press the @/1 button and display “

/

a =

”.

Check that the C error is below 100 and ADER is below 2

9. Press the x/Z button, next press the x/Z “PGM” button,

and remove the continuously recorded disc.

Note 1 : If the C error and ADER are above other than the speci-

fied value at points a (step 8. in the above) or b (step 7. in
the above), the focus bias adjustment may not have been
carried out properly. Adjust perform the beginning again.

5-16. AUTO GAIN CONTROL OUTPUT LEVEL

ADJUSTMENT

Be sure to perform this adjustment when the optical pick-up is re-
placed.
If the adjustment results becomes “Adjust NG!”, the optical pick-
up may be faulty or the servo system circuits may be abnormal.

5-16-1. CD Auto Gain Control Output Level Adjustment

Adjusting Procedure :
1. Insert the check disc (MD) TDYS-1.
2. Rotate the AMS knob to display “AG Set (CD)” (C11).
3. When the @/1 button is pressed, the adjustment will be

performed automatically.
“Complete! !” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (CD)” (C11).

4. Press the x/Z “PGM” button to remove the disc.

5-16-2. MO Auto Gain Control Output Level Adjustment

Adjusting Procedure :
1. Insert the reference disc (MDW-74/GA-1) for recording.
2. Rotate the AMS knob to display “AG Set (MO)” (C10).
3. When the @/1 button is pressed, the adjustment will be

performed automatically.
“Complete! !” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (MO)” (C10).

4. Press the x/Z “PGM” button to remove the disc.

Advertising