Adaptation to different types of gas, 1 changing nozzles, Instructions for the installer – Smeg A31X-6 User Manual

Page 10

Advertising
background image

Instructions for the Installer

12

3. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, switch off the
power supply to the appliance.

The cooking hob of the cooker is preset for natural gas at a pressure of
1.0 kPa. In the case of functioning with other types of gas the burner
nozzles must be changed and the minimum flame adjusted on the gas
taps. Replace the burner nozzles as indicated in the table of the gas to be
used.

Changing nozzles

3.1

1.

Extract the grids and remove all the caps and flame-spreader
crowns;

2.

unscrew the burner nozzles with a 7 mm socket wrench;

3.

proceed with replacing the burner nozzles in accordance with the
table for the gas in question.

Advertising