Troubleshooting – Schwinn 460 User Manual

Page 28

Advertising
background image

Problem

Check

Solution

No display/partial display/unit

will not turn on

Electrical (wall) outlet

If outlet does not function, use a properly

functioning outlet.

Connection at front of unit

Connection should be secure and undamaged.

Replace adapter or connection at unit if damage

appears.

Main console cable integrity

Replace cable if wires appear crimped or cut.

Main console cable connections/

orientation

Confirm cable is connected securely at the back

of the console and at the base of the console

mast.

Console display for cracks or other

damage

Replace console if damaged.

Console Display

Replace computer if console only has partial

display.

Unit operates but Telemetric

HR not displayed

Chest Strap

Make sure strap is directly against skin and

contact area is moist. Strap should be Polar

®

compatible.

Interference

Try moving unit away from sources of interference

(TV, Microwave, etc).

Chest Strap

Connect strap to a functioning Polar

®

compatible

device to see if it works. If it does not function,

replace strap. If strap works with other devices

but not with the Schwinn

®

460, replace HR

receiver.

No speed/RPM reading

Main console cable integrity

All wires in cable should be intact. Replace cable

if wires appear crimped or cut.

Main console cable connections/

position

Confirm cable is securely connected and

properly positioned. Small latch on connector

should line up and snap into place.

Magnet position (requires shroud

removal)

Replace flywheel or entire main assembly if you

do not see a magnet.

RPM Sensor (requires shroud

removal)

RPM sensor should be aligned with magnet

and connected to data cable. Re-align sensor

if necessary. Replace if there is any damage to

sensor or connecting wire.

Troubleshooting

Owner’s Manual

26