18 |

CHAPTER 2 – CONFIGURING YOUR HUB

To connect the computer

or room control

system to your hub

Connect your hub to the computer or room control system using the female RS-232
connector.

NOTE
The female RS-232 connector is for room control only.

To enable your hub’s

room control mode

1. Select System > Settings.

The SMART Hub SE240 Settings dialog box appears.

2. Select Administration, and then select the Enable room control with RS-232

check box.

3. Press Apply All.

To configure your serial

interface settings

You can’t configure the SMART Hub SE240’s serial interface settings. Therefore,
configure your computer’s serial communication program, such as Microsoft®
HyperTerminal or your room control system’s serial communication settings, to the
following values.

To verify that the

serial interface is

in room control mode

1. Turn on your communication program.

2. Configure your communication program as documented in the previous section.

3. Press ENTER.

If your configuration is correct and the SMART Hub SE240 is in room control
mode, the > character appears.

Setting

Value

Data rate

9600 bps

Data bits

8

Parity

None

Stop bits

1

Flow control

None