Keating Of Chicago CMG User Manual

Page 2

Advertising
background image

9.

Remove flue from fryer vessel by
removing six screws out of tabs. Inspect
flue for cracks or damage and replace if
necessary.

10.

Remove drain valve from fryer vessel.

REPLACEMENT:
1.

Slide flue onto tabs on back of new fryer
vessel until it contacts back of vessel.
Drill holes into vessel tabs through
existing holes in flue and fasten flue to
vessel tabs with six sheet metal screws
and set on floor next to old vessel.

2.

Replace drain valve on new fryer vessel
after applying high temperature sealant
on vessel threads.

3.

Remove gas manifold with support
brackets from vessel by removing four
screws and lockwashers joining brackets

to sides of vessel. Leave constant and
runner pilot tubing and gas manifold
connected to manifold brackets and
assemble to new vessel.

4.

Carefully lower vessel and flue into
cabinet. Check fryer vessel fit in cabinet
before proceeding with assembly.

5.

Replace splashback onto vessel with
sheet metal screws and pop rivets.

6.

Replace canopy onto cabinet with two
sheet metal screws.

7.

Tighten union in tailpiece assembly.

8.

Replacement of components:
a. Replace Hi-Limit control bulb into

vessel.

b. Replace thermostat bulb into vessel.

www.keatingofchicago.com

1-800-KEATING

S E R V I C E I N S T R U C T I O N S

REMOVAL AND REPLACEMENT OF

FRONT DRAIN FRYER VESSEL

(MODELS WITH UNI-POT)

CONTINUED

page 2

Part #031289

Rev. 1

ECO 2110

Date 6/11/98

Advertising