ENGLISH

39

MAINTENANCE WORK ON CHASSIS AND ENGINE

»

Battery (MXC/EXC)

The battery is located under the seat and is maintenance-free.

It is not necessary to check the electrolyte level or to refill water. Simply keep

the battery poles clean and slightly grease them with an acid-free grease if

necessary.

Removing the battery:

First disconnect the negative and then the positive pole of the battery.

Remove the filter box cover and unhitch both rubber bands

[1].

Remove battery.Install the battery with the terminals facing the front (see illus-

tration), connecting the negative terminal post to the battery last.

– IF ELECTROLYTE (SULPHURIC ACID) LEAKS FROM THE BATTERY, PROCEED WITH

GREAT CARE. THE ELECTROLYTE CAN CAUSE SEVERE BURNS.

– IN THE CASE OF SKIN CONTACT RINSE THOROUGHLY WITH WATER.

– IN THE CASE OF CONTACT WITH THE EYES, THOROUGHLY RINSE EYES WITH

WATER FOR AT LEAST 15 MINUTES. IMMEDIATELY CONSULT A DOCTOR.

– THE BATTERY IS A CLOSED MODEL BUT CAN NEVERTHELESS EMIT EXPLO-

SIVE GASES. AVOID SPARKS AND OPEN FIRE NEAR THE BATTERY.

– DEFECTIVE BATTERIES MUST BE STORED OUT OF THE REACH OF CHILDREN.

ENSURE PROPER DISPOSAL OF DISCARDED BATTERIES.

– TO AVOID DAMAGE, DO NOT REMOVE THE LOCKING BAR

[2] !

– NEVER DISCONNECT THE BATTERY WHILE THE ENGINE IS RUNNING. THIS

WILL DESTROY THE RECTIFIER-REGULATOR.

– THE BATTERY MUST BE INSTALLED WITH THE TERMINALS FACING THE FRONT

(AS SHOWN IN THE ILLUSTRATION), OTHERWISE ELECTROLYTE CAN ESCAPE.

BATTERY STORAGE:

When preparing the motorcycle for a longer period of standstill, remove the

battery and recharge it. Storage temperature: 0 - 35°C (30 - 95°F). Do not

expose to direct sunlight.

Charging the battery

Remove the battery and check the charging level. Use a voltmeter to

measure the voltage between the battery poles (off-load voltage).

Accurate results can only be obtained if the battery has neither been charged

nor discharged during a period of 30 minutes preceding the measuring.

If the battery is empty, it can be recharged for a maximum period of

10 hours at 0.4 A and a maximum of 14.4 V.

– TO AVOID DAMAGE, DO NOT REMOVE THE LOCKING BAR.

– ALWAYS CONNECT THE BATTERY TO THE CHARGING UNIT BEFORE TURNING

THE CHARGING UNIT ON.

– WHEN RECHARGING THE BATTERY IN CLOSED ROOMS THERE IS SUFFICIENT

VENTILATION. EXPLOSIVE GASES ARE RELEASED DURING THE BATTERY

CHARGING PROCESS.

– CHARGING TIME AND CHARGING VOLTAGE SHOULD NOT EXCEED THE STATED

VALUES. OTHERWISE ELECTROLYTE WILL BE RELEASED THROUGH THE SAFETY

VALVES.

– AVOID QUICK CHARGING IF POSSIBLE.

VOLT

1

2

off load voltage

Volt

charging level

%

charging time

0,4 A

charging voltage

>12,7

~12,5

~12,2

~12,0

~11,8

100

75

50

25

0

––

4 h

7 h

11 h

14 h

Max.

14,4 V