TECHNICAL DATA

230 V AC - 50 Hz

Top conventional oven
– Top element

0.70 kW

– Bottom element

1.10 kW

– Grill element

2.10 kW

Bottom fan oven
– Fan element

2.50 kW

Vitroceramic hob
– Front left

1.70 kW

– Back left

1.20 kW

– Back right

2.10 kW

– Front right

1.20 kW

Maximum power rating
– Top oven

2.10 kW

– Bottom oven

2.50 kW

Oven lamp

0.015 kW

300 °C, miniature edison screw

Fan motor

0.025 kW

Maximum usable power
(diversity not applied)

10.86 kW

CONNECTING THE MAINS CABLE

– Remove the two screws securing the

cover plate A behind the cooker.

– Remove the screw C from the cable

clamp.

– Insert the mains cable (type H05RR-F)

of minimum 6 mm

2

section into the

cable protector P.

– Connect the phase and earth cables to

the mains terminal connection block
B.

EARTH

N

NEUTRAL

L

LIVE

– Refit the cable clamp so that it clamps

the outer sleeving of the cable.

– Refit the cover plate A.

L

N

Green &Yellow
(Earth)

Brown

(Live)

Blue

(Neutral)

P

C

B

Fig. 10.1

A