Kenwood TK-3173 User Manual

Page 32

Advertising
background image

23

2

Press the key programmed as VOX.

The current VOX Gain level appears.

3

Press the <B and C> keys or rotate the selector to
increase or decrease the VOX Gain level.

The VOX Gain can be adjusted from levels 1 to 10.

4

While adjusting the gain level, speak into the headset
microphone as you would while under normal operation, to
test the sensitivity level.

When the microphone recognizes a sound, the LED lights
orange. This allows you to determine a suitable level where
background noise will not activate VOX operation while
speaking into the microphone will.

The transceiver does not transmit your voice during this test
procedure.

5

Press the S key to save the setting.

To activate the VOX function:
1

Connect the headset to the transceiver.

The VOX function does not activate when a headset is not
connected to the accessory terminal of the transceiver.

2

Press and hold the key programmed as VOX for
2 seconds.

The VOX indicator (

) appears on the display.

3

To turn the VOX function OFF, press and hold the VOX
key again, for 2 seconds.

Note:
◆ If a speaker/ microphone is connected to the transceiver while the

VOX function is switched ON and the VOX Gain Level is configured
to a higher, more sensitive level, louder received signals may cause
the transceiver to start transmission.

◆ When you operate the VOX function, you must use an optional

KHS-1, KHS-21, or KHS-22 accessory.

Advertising
This manual is related to the following products: