7.

Lift out the flow regulator assembly,
switch assembly and the heater tank
from the case.

8.

Carefully separate the flow regulator
assembly from the switch assembly,
inlet connector and heater tank by
gently pulling apart.

9.

Make a note of the positions of all the
wiring on top of the heater tank.

10.

Remove the screw that holds the
green earth wire to the thermal trip.

13.

Refit the components in reverse order.
Make sure that the electrical wires and
‘O’ seals are installed in the correct
positions.

Flow Regulator
Assembly

Switch
Assembly

Inlet
Connector

11.

Ease the thermal trip away from the
heater tank.

Caution!

Do not press printed disc

on the thermal trip as this will make
the component unserviceable.

12.

Remove the screw that holds the two
blue wires to the top of the heater tank.

Green Earth
Wire

Blue Neutral
Wire

Heater
Tank

Thermal
Trip