KWC MARLINO 802 141 User Manual

Kwc marlino, Installation and service instructions, Concealed pressure balanced bath and shower mixer

Advertising
background image

Inlet:
hot
water

Inlet:
cold
water

with integrated by-pass -

twin ell not required

Rough in:

K.37.P4.02.931.23

Trim set:
KWC MARLINO

K.21.P4.00

Rough in:

K.37.P4.01.931.23

4 port with diverter

Trim set:
KWC MARLINO

K.20.P4.00

Rough in:

K.37.P4.03.931.23

Trim set:
KWC MARLINO

K.21.P4.00

+

4 port without diverter

/

3 port

802 141

Installation and service instructions

03/00

KWC

MARLINO

Concealed pressure balanced bath and shower mixer

This product is precision engineered to provide superior
performance provided it is installed and operated in
accordance with these recommendations. In order to
fully enjoy the comfort, safety and reliability of your

pressure balancing valve, be certain to familiarize yourself with these
instructions.

Failure to follow these instructions may cause damage or improper
operation and nullify the warranty!

Maintenance:

A)

To clean your faucets and accessories simply wipe them with a
wet, soapy cloth, immediately rinse off with cold watre and wipe dry with

a

soft, damp cloth or towel.

B)

Most bathroom and kitchen cleaners contain aggressive
(acidic / corrosive) chemicals or abrasives which will harm the
finish and cause operational problems.

C)

Use of these products voids the manufacturer's warranty.

!

Operation:

A counterclockwise rotation opens the valve beginning with cold water.
Preventing accidental scalding.

An adjustable hot limit stop reduces risk of exposure to extremely hot
water.

Clockwise rotation of the handle closes the valve.

The valve's comfort zone ensures a safe,
reliable and precise adjustment of mixed
water temperature in the range from
95° F (35°C) to 105°F (40°C).

The featherlight touch of the handle
provides simple and easy control for
the young or elderly.

Schweiz, Suisse:
KWC AG
Hauptstrasse
CH-5726 Unterkulm

Tel. : 062 768 67 77
Fax : 062 768 61 62

USA:
KWC FAUCETS INC.
1770 Corporate Drive # 580
Norcross, GA 30093

Phone: 678 334 2121
Fax:

678 334 2128

!

Operating data
Ideal operating pressure

: 3 bar (45 PSI)

Max. operating pressure

: 5 bar (70 PSI)

Equal pressures cold/warm recommended
Ideal water temperature

: 65 °C (149°F)

Max. hot water temperature

: 90 °C (194°F)

Attention:
Before installation flush pipes thoroughly!