5

Malfunction:

Hot and cold reversed

Tub filler shower head drips after shutting off the
valve.

Shower insufficiently hot

No flow of hot or cold water

Valve body too deep in wall

Cause:

Hot and cold water supplies have been connected in
reverse.

Water remains in the shower piping.
(This is normal)

Incorrect setting of the stop ring causing a partially
opened cartridge.

Cartridge inlet O-ring seal is faulty.

Hot limit stop incorrectly set.

Either the hot or cold side is not fully pressurized.
Debris caught inside the inlet of the cartridge.

No engagement between escutcheon and plastic
driver.

Improper installation.

Remedy:

Rotate cartridge as described in "Back-to-back
installation".

Allow approximately 3 - 5 minutes to drain column, or
push lever on tub spout to the tub fill position * .

Reset the hot limit stop ring as described in rough-in
installation.

Check the O-ring for cuts or damage and replace if
necessary.

Refer to the instruction: Check hot water temperature.

Be sure service stops are both fully open and system
is pressurized.

Remove cartridge and flush out or remove any debris
lodged inside the hot or cold inlets.
Install either the 1/2" or 3/4" extension kit.

Install either the 1/2" or 3/4" extension kit.

Never try to stop dripping by applying excessive force to the handle when closing the valve!

!