ADJUSTMENT

Test Equipment Required for Alignment

Test Equipment

Major Specifications

1.

Standard Signal Generator

Frequency Range

136 to 174MHz.

(SSG)

Modulation

Frequency modulation and external modulation.

Output

-127dBm/0.1µV to greater than -47dBm/1mV

2.

Power Meter

Input Impedance

50Ω.

Operation Frequency

136 to 174MHz.

Measurement Range

Vicinity of 10W

3.

Deviation Meter

Frequency Range

136 to 174MHz.

4.

Digital Volt Meter

Measuring Range

10mV to 10V DC

(DVM)

Input Impedance

High input impedance for minimum circuit loading.

5.

Oscilloscope

DC through 30MHz.

6.

High Sensitivity

Frequency Range

10Hz to 1000MHz.

Frequency Counter

Frequency Stability

0.2ppm or less.

7.

Ammeter

5A.

8.

AF Volt Meter

Frequency Range

50Hz to 10kHz.

(AF VTVM)

Voltage Range

1mV to 10V.

9.

Audio Generator (AG)

Frequency Range

50Hz to 5kHz or more.

Output

0 to 1V.

10.

Distortion Meter

Capability

3% or less at 1kHz.

Input Level

50mV to 10Vrms.

11.

Spectrum Analyzer

Measuring Range

DC to 1GHz or more

12.

Tracking Generator

Center frequency

50kHz to 600MHz

Output Voltage

100mV or more

13.

8Ω Dummy Load

Approx. 8Ω, 3W.

14.

Regulated Power Supply

5V to 10V, approx. 3A
Useful if ammeter equipped.

The following parts are required for

adjustment

1. Antenna connector adapter

The antenna connector of this radio uses an SMA terminal.
Use an antenna connector adapter [SMA(f) – BNC(f) or

SMA(f) – N(f)] for adjustment. (The adapter is not provided as
an option, so buy a commercially-available one.)

2. Repair Jig (Chassis)

Use jig (part No.: A10-4082-03) for repairing the TK-2160.

Place the TX-RX unit on the jig and fit it with screws.

The jig facilitates the voltage check and protects the final

amplifier FET when the voltage on the flow side of the TX-RX
unit is checked during repairs.

3. Battery Jig (W05-0909-00)

+ Terminal (Red)

– Terminal (Black)

Connect the power cable properly between the battery jig

installed in the transceiver and the power supply, and be sure
output voltage and the power supply polarity prior to switching
the power supply ON, otherwise over voltage and reverse
connection may damage the transceiver, or the power supply
or both.

When using the battery jig in user mode, the transceiver

assumes that a lithium-ion battery pack is attached to the
transceiver. In adjustment mode, battery type detection is
not performed. Refer to page 10 for details.

Note: When using the battery jig, you must measure the
voltage at the terminals of the battery jig. Otherwise, a slight
voltage drop may occur within the power cable, between the
power supply and the battery jig, especially while the
transceiver transmits.

+ Terminal

(Red)

– Terminal
(Black)

C3

100

m

/25V

C2

470P/25V

C1

100P/25V

R1

1.8M

S

+

Power
supply

Power cable

SCHEMATIC DIAGRAM

Advertising