Tk-2160, Adjustment – Kenwood TK-2160 User Manual

Page 29

Advertising
background image

TK-2160

29

ADJUSTMENT

Item

Condition

Measurement

Adjustment

Specifications/

Test equipment

Terminal

Parts

Method

Remark

1.BPF Wave

TEST CH:Center

SSG

ANT

Programming

RSSI MAX

form ADJ

Low

DVM

RSSI

Software:KPG-82D

Low’

Oscilloscope

Center

AF VTVM

High’

High

SSG otuput:–103 dBm(1.58µV)

2.Sesitivity

TEST CH:Center

ANT

Check

12dB SINAD or

check

Low

more

[Wide]

Low’

Center

High’

High

SSG otuput:–117 dBm(0.3µV)
SSG MOD:3kHz

3.Sesitivity

TEST CH:Center

Check

12dB SINAD or

check

SSG otuput:–115 dBm(0.4µV)

more

[Narrow]

SSG MOD:1.5kHz

4.Squelch

TEST CH:Low

Programming

write

Squelch open

threshold

SSG otuput:–122 dBm(0.18µV)

Software:KPG-82D

writing

SSG MOD:3.0kHz

[Wide]

5.Squelch

TEST CH:Center

Squelch open

threshold

SSG otuput:–120 dBm(0.22µV)

writing

SSG MOD:1.5kHz

[Narrow]

6.Squelch

TEST CH:High

Squelch open

tight

SSG otuput:–117 dBm(0.3µV)

writing

SSG MOD:3.0kHz

[Wide]

7.Squelch

TEST CH:Center

Squelch open

tight

SSG otuput:–116 dBm(0.35µV)

writing

SSG MOD:1.5kHz

[Narrow]

8.RSSI writing TEST CH:Center

[Wide]

SSG otuput:–123 dBm(0.16µV)
SSG MOD:off

9.RSSI writing TEST CH:Center

[Narrow]

SSG otuput:–122 dBm(0.18µV)
SSG MOD:off

Receiver Section

Item

Condition

Measurement

Adjustment

Specifications/

Test equipment

Terminal

Parts

Method

Remark

15.BATT

1) BATT terminal voltage:5.5V Power meter

ANT

Check

Blinking of LED

Detection

PTT:ON

DVM

BATT terminal

Check

2) BATT terminal voltage:7.5V

No blinking of

PTT:ON

LED

Advertising