This Cut-off saw is equipped with a grounded 3-wire power cord with a 3-prong
plug. If the power cord will not fit into the wall plug, an approved adapter can be
used as long as it is connected to the center screw in the wall plate. See Figure 1
and the steps below to use an AC grounding adapter:

1. Remove the cover plate mounting screw.

2. Insert the AC grounding adapter into the bottom receptacle so the green

grounding lug fits over the screw hole.

3. Install the mounting screw back into the cover plate securely affixing the

adapter to the receptacle.

N

Neevveerr m

mo

od

diiffyy tth

hee eelleeccttrriiccaall aad

daap

ptteerr b

byy ccu

uttttiin

ng

g o

offff tth

hee

g

grro

ou

un

nd

diin

ng

g p

prro

on

ng

g sso

o iitt w

wiillll ffiitt iin

ntto

o u

un

naap

pp

prro

ovveed

d,, u

un

n--g

grro

ou

un

nd

deed

d eelleeccttrriiccaall rreecceep

p--

ttaacclleess.. FFaaiillu

urree tto

o ffo

ollllo

ow

w tth

hiiss p

prro

occeed

du

urree cco

ou

ulld

d rreessu

ulltt iin

n b

bu

urrn

nss,, sseevveerree eelleeccttrrii--

ccaall ssh

ho

occkk,, o

orr eevveen

n d

deeaatth

h..

If you have questions about connecting the Cut-off saw, contact a certified
electrician to install the proper circuitry needed for this and other power tools
you use. Repair or replace any damaged electrical wiring IIM

MM

ME

ED

DIIA

AT

TE

EL

LY

Y..

E

EX

XT

TE

EN

NS

SIIO

ON

N C

CO

OR

RD

D U

US

SA

AG

GE

E

Extension cords are not recommended for use with this saw. Extension cords, if
used, must be properly grounded with a 3-prong plug on one and a 3-hole recepta-
cle on the other. D

DO

O N

NO

OT

T u

ussee g

grro

ou

un

nd

diin

ng

g aad

daap

ptteerrss w

wiitth

h aan

n eexxtteen

nssiio

on

n cco

orrd

d..

Extension cords must be UL listed and use a minimum of 18 A.W.G. wiring.
Extension cords should never exceed 25 feet in length. Extension cords, that are too
long, cause a voltage drop over the extra distance causing the saw motor to run
slower with the possibility of causing damage to the motor. Using extension cords
with smaller than the recommended wire gauge run the risk of getting too hot, melt-
ing, and/or causing fires. See table, “Extension Cord Specifications”, on page 26.

U

US

SE

E R

RE

EC

CO

OM

MM

ME

EN

ND

DE

ED

D A

AC

CC

CE

ES

SS

SO

OR

RIIE

ES

S.. Consult the owners manual for recommend-

ed accessories. The use of improper accessories may cause cause risk of injury.

N

NE

EV

VE

ER

R S

ST

TA

AN

ND

D O

ON

N T

TO

OO

OL

L.. Serious injury could occur if the tool is tipped or if

the cutting tool is unintentionally contacted.

C

CH

HE

EC

CK

K D

DA

AM

MA

AG

GE

ED

D P

PA

AR

RT

TS

S.. Before further use of the tool, a guard or other part

that is damaged should be carefully checked to determine that it will operate
properly and perform its intended function. Check for alignment of moving
parts, binding of moving parts, breakage of parts, mounting and any other con-
ditions that may affect its operation. A guard or other part that is damaged
should be properly repaired or replaced.

D

DIIR

RE

EC

CT

TIIO

ON

N O

OFF FFE

EE

ED

D.. Only feed work into a blade or cutter against the direc-

tion of rotation of the blade or cutter.

G

GR

RO

OU

UN

ND

DIIN

NG

G IIN

NS

ST

TR

RU

UC

CT

TIIO

ON

NS

S

N

NE

EV

VE

ER

R u

ussee aap

pp

plliiaan

ncceess o

orr eeq

qu

uiip

pm

meen

ntt tth

haatt h

haavvee m

mo

otto

orrss

w

wiitth

h aau

utto

om

maattiicc rreesseett o

ovveerrllo

oaad

d p

prro

otteeccttiivvee d

deevviicceess.. T

Th

heessee p

prro

otteeccttiivvee d

deevviicceess

ccaan

n ccaau

ussee u

un

neexxp

peecctteed

d ssttaarrttu

up

pss tth

haatt ccaan

n ccaau

ussee p

prro

op

peerrttyy d

daam

maag

gee,, sseevveerree p

peerr--

sso

on

naall iin

njju

urryy,, o

orr d

deeaatth

h..

The electrical power source for this Cut-off saw M

MU

US

ST

T be grounded in order to

prevent possible electric shock or even death should the tool malfunction or break
down. Grounding provides a path of least resistance for electric current thus reduc-
ing the risk of electrical shock. The power source must also use a minimum 20A
service. Multiple power tools should never be used on the same circuit at the same
time.

FFaaiillu

urree tto

o p

prro

op

peerrllyy g

grro

ou

un

nd

d tth

hiiss C

Cu

utt--o

offff ssaaw

w cco

ou

ulld

d rreessu

ulltt iin

n

b

bu

urrn

nss,, sseevveerree eelleeccttrriiccaall ssh

ho

occkk,, aan

nd

d eevveen

n d

deeaatth

h.. T

Th

hiiss iiss eessp

peecciiaallllyy ttrru

uee iiff u

usseed

d iin

n

d

daam

mp

p o

orr w

weett llo

occaattiio

on

nss o

orr n

neeaarr m

meettaalllliicc p

pllu

um

mb

biin

ng

g.. T

Th

hee rreeaaccttiio

on

n ffrro

om

m eelleeccttrriiccaall

ssh

ho

occkk cco

ou

ulld

d p

po

ossssiib

bllyy ccaau

ussee yyo

ou

urr h

haan

nd

dss tto

o m

maakkee cco

on

nttaacctt w

wiitth

h tth

hee ccu

uttttiin

ng

g tto

oo

ollss..

N

No

ott aallll o

ou

uttlleettss aarree p

prro

op

peerrllyy g

grro

ou

un

nd

deed

d,, rreeg

gaarrd

dlleessss o

off tth

hee

ttyyp

pee o

off rreecceep

pttaaccllee tth

heeyy h

haavvee.. IIff yyo

ou

u aarree n

no

ott ssu

urree iiff tth

hee rreecceep

pttaaccllee iiss p

prro

op

peerrllyy

g

grro

ou

un

nd

deed

d o

orr n

no

ott,, cco

on

nssu

ulltt aa cceerrttiiffiieed

d eelleeccttrriicciiaan

n.. T

Th

hee A

AC

C rreecceep

pttaaccllee m

mu

usstt b

bee

p

prro

otteecctteed

d b

byy aa d

du

uaall eelleem

meen

ntt ttiim

mee d

deellaayy o

orr aa cciirrccu

uiitt b

brreeaakkeerr..

5

UNGROUNDED AC RECEPTACLE

GROUNDED RECEPTACLE

GROUNDING ADAPTER

CUT-OFF SAW POWER CORD

CUT-OFF SAW POWER CORD

COVERPLATE

MOUNTING SCREW

FIGURE 1. CONNECTING THE CUT-OFF SAW TO THE AC POWER RECEPTACLE