Kawasaki 691204 User Manual
Page 4
This Cut-off saw is equipped with a grounded 3-wire power cord with a 3-prong
plug. If the power cord will not fit into the wall plug, an approved adapter can be
used as long as it is connected to the center screw in the wall plate. See Figure 1
and the steps below to use an AC grounding adapter:
1. Remove the cover plate mounting screw.
2. Insert the AC grounding adapter into the bottom receptacle so the green
grounding lug fits over the screw hole.
3. Install the mounting screw back into the cover plate securely affixing the
adapter to the receptacle.
N
Neevveerr m
mo
od
diiffyy tth
hee eelleeccttrriiccaall aad
daap
ptteerr b
byy ccu
uttttiin
ng
g o
offff tth
hee
g
grro
ou
un
nd
diin
ng
g p
prro
on
ng
g sso
o iitt w
wiillll ffiitt iin
ntto
o u
un
naap
pp
prro
ovveed
d,, u
un
n--g
grro
ou
un
nd
deed
d eelleeccttrriiccaall rreecceep
p--
ttaacclleess.. FFaaiillu
urree tto
o ffo
ollllo
ow
w tth
hiiss p
prro
occeed
du
urree cco
ou
ulld
d rreessu
ulltt iin
n b
bu
urrn
nss,, sseevveerree eelleeccttrrii--
ccaall ssh
ho
occkk,, o
orr eevveen
n d
deeaatth
h..
If you have questions about connecting the Cut-off saw, contact a certified
electrician to install the proper circuitry needed for this and other power tools
you use. Repair or replace any damaged electrical wiring IIM
MM
ME
ED
DIIA
AT
TE
EL
LY
Y..
E
EX
XT
TE
EN
NS
SIIO
ON
N C
CO
OR
RD
D U
US
SA
AG
GE
E
Extension cords are not recommended for use with this saw. Extension cords, if
used, must be properly grounded with a 3-prong plug on one and a 3-hole recepta-
cle on the other. D
DO
O N
NO
OT
T u
ussee g
grro
ou
un
nd
diin
ng
g aad
daap
ptteerrss w
wiitth
h aan
n eexxtteen
nssiio
on
n cco
orrd
d..
Extension cords must be UL listed and use a minimum of 18 A.W.G. wiring.
Extension cords should never exceed 25 feet in length. Extension cords, that are too
long, cause a voltage drop over the extra distance causing the saw motor to run
slower with the possibility of causing damage to the motor. Using extension cords
with smaller than the recommended wire gauge run the risk of getting too hot, melt-
ing, and/or causing fires. See table, “Extension Cord Specifications”, on page 26.
U
US
SE
E R
RE
EC
CO
OM
MM
ME
EN
ND
DE
ED
D A
AC
CC
CE
ES
SS
SO
OR
RIIE
ES
S.. Consult the owners manual for recommend-
ed accessories. The use of improper accessories may cause cause risk of injury.
N
NE
EV
VE
ER
R S
ST
TA
AN
ND
D O
ON
N T
TO
OO
OL
L.. Serious injury could occur if the tool is tipped or if
the cutting tool is unintentionally contacted.
C
CH
HE
EC
CK
K D
DA
AM
MA
AG
GE
ED
D P
PA
AR
RT
TS
S.. Before further use of the tool, a guard or other part
that is damaged should be carefully checked to determine that it will operate
properly and perform its intended function. Check for alignment of moving
parts, binding of moving parts, breakage of parts, mounting and any other con-
ditions that may affect its operation. A guard or other part that is damaged
should be properly repaired or replaced.
D
DIIR
RE
EC
CT
TIIO
ON
N O
OFF FFE
EE
ED
D.. Only feed work into a blade or cutter against the direc-
tion of rotation of the blade or cutter.
G
GR
RO
OU
UN
ND
DIIN
NG
G IIN
NS
ST
TR
RU
UC
CT
TIIO
ON
NS
S
N
NE
EV
VE
ER
R u
ussee aap
pp
plliiaan
ncceess o
orr eeq
qu
uiip
pm
meen
ntt tth
haatt h
haavvee m
mo
otto
orrss
w
wiitth
h aau
utto
om
maattiicc rreesseett o
ovveerrllo
oaad
d p
prro
otteeccttiivvee d
deevviicceess.. T
Th
heessee p
prro
otteeccttiivvee d
deevviicceess
ccaan
n ccaau
ussee u
un
neexxp
peecctteed
d ssttaarrttu
up
pss tth
haatt ccaan
n ccaau
ussee p
prro
op
peerrttyy d
daam
maag
gee,, sseevveerree p
peerr--
sso
on
naall iin
njju
urryy,, o
orr d
deeaatth
h..
The electrical power source for this Cut-off saw M
MU
US
ST
T be grounded in order to
prevent possible electric shock or even death should the tool malfunction or break
down. Grounding provides a path of least resistance for electric current thus reduc-
ing the risk of electrical shock. The power source must also use a minimum 20A
service. Multiple power tools should never be used on the same circuit at the same
time.
FFaaiillu
urree tto
o p
prro
op
peerrllyy g
grro
ou
un
nd
d tth
hiiss C
Cu
utt--o
offff ssaaw
w cco
ou
ulld
d rreessu
ulltt iin
n
b
bu
urrn
nss,, sseevveerree eelleeccttrriiccaall ssh
ho
occkk,, aan
nd
d eevveen
n d
deeaatth
h.. T
Th
hiiss iiss eessp
peecciiaallllyy ttrru
uee iiff u
usseed
d iin
n
d
daam
mp
p o
orr w
weett llo
occaattiio
on
nss o
orr n
neeaarr m
meettaalllliicc p
pllu
um
mb
biin
ng
g.. T
Th
hee rreeaaccttiio
on
n ffrro
om
m eelleeccttrriiccaall
ssh
ho
occkk cco
ou
ulld
d p
po
ossssiib
bllyy ccaau
ussee yyo
ou
urr h
haan
nd
dss tto
o m
maakkee cco
on
nttaacctt w
wiitth
h tth
hee ccu
uttttiin
ng
g tto
oo
ollss..
N
No
ott aallll o
ou
uttlleettss aarree p
prro
op
peerrllyy g
grro
ou
un
nd
deed
d,, rreeg
gaarrd
dlleessss o
off tth
hee
ttyyp
pee o
off rreecceep
pttaaccllee tth
heeyy h
haavvee.. IIff yyo
ou
u aarree n
no
ott ssu
urree iiff tth
hee rreecceep
pttaaccllee iiss p
prro
op
peerrllyy
g
grro
ou
un
nd
deed
d o
orr n
no
ott,, cco
on
nssu
ulltt aa cceerrttiiffiieed
d eelleeccttrriicciiaan
n.. T
Th
hee A
AC
C rreecceep
pttaaccllee m
mu
usstt b
bee
p
prro
otteecctteed
d b
byy aa d
du
uaall eelleem
meen
ntt ttiim
mee d
deellaayy o
orr aa cciirrccu
uiitt b
brreeaakkeerr..
5
UNGROUNDED AC RECEPTACLE
GROUNDED RECEPTACLE
GROUNDING ADAPTER
CUT-OFF SAW POWER CORD
CUT-OFF SAW POWER CORD
COVERPLATE
MOUNTING SCREW
FIGURE 1. CONNECTING THE CUT-OFF SAW TO THE AC POWER RECEPTACLE