KVH Industries TracVision 6 User Manual

Page 61

Advertising
background image

9. Type HALT<cr>.

10. Type

DEBUGON<cr>

.

11. Type =LSTEST<cr>.

12. Type EL,300<cr>.

13. Type

=CALGYRO<cr>.

Verify that the Antenna

Gyro Azimuth scale factor is between -0.00090 and
-0.00110 and the Antenna Gyro Elevation scale
factor is between 0.00090 and 0.00110.

14. Type

=SERNUM,<serial number><cr>

, where

<serial number> = the system serial number that
you recorded in Step 2.

15. Type

ZAP<cr>

to restart/reinitialize the system.

KVH recommends that you complete the following additional
steps to speed satellite acquisition and improve system
performance:

16. Type

HALT<cr>

while the system is performing

the limit switch initialization routine.

17. Determine your vessel’s current latitude and

longitude to the nearest degree.

18. Type

GPS,AA,B,CCC,D<cr>

where

• AA = Latitude in degrees

• B = N (North) or S (South)

• CCC = Longitude in degrees

• D = E (East) or W (West)

19. Verify that the response shows the correct

parameters.

20. Type

ZAP

to restart/reinitialize the system.

54-0166

60

TracVision 6 Technical Manual