E.2 manual positioning commands – KVH Industries TracVision 6 User Manual

Page 78

Advertising
background image

Maintenance Port Parser Commands

54-0166

83

Enter Serial Number

Function:

enters system serial number

Command:

=SERNUM,XXXXXXXX

Where:

XXXXXXXX = the system’s serial number

Response:

SN = XXXXXXXX

Configure System

Function:

configures software for a particular system model

Command:

=TVXXXX

Where:

XXXX = system model (i.e., G6HP)

Response:

system configures software and antenna restarts

E.2

Manual Positioning Commands

To execute the following commands, first put the antenna unit in
idle mode by typing HALT and pressing “ENTER.” Positioning
commands may be entered after the antenna comes to rest.

Azimuth Angle

Function:

commands a manual azimuth angle that the
mechanism moves to

Command:

AZ,XXXX (range is 0000-3599)

Argument:

desired azimuth angle of the mechanism relative to
external magnetic reference, or baseplate fwd,
000°-359.9°

Response:

echoes the command; mechanism moves at a
fixed velocity

Elevation Angle

Function:

commands a manual elevation angle that the
mechanism moves to

Command:

EL,XXX (range is 100-850)

Argument:

desired elevation angle of the mechanism relative to
up, or external sensor attitude reference, 10.0°-
85.0°

Response:

echoes the command; mechanism moves at a
fixed velocity

Table E-2
Manual Positioning Commands

Advertising