Kohler 120V Bath with Airjets 1198326-2-A User Manual

Page 14

Advertising
background image

Troubleshooting (cont.)

Symptoms

Probable Causes

Recommended Action

5.

Blower motor starts, some

but not all airjets are

working.

A.

Blower motor speed is too low.

A.

Increase speed.

B.

Blower motor inlet is blocked.

B.

Clean blower motor inlet.

C.

Blower motor does not work.

C.

Replace the blower motor.

D.

Blower motor discharge is

blocked.

D.

Clear blockage.

E.

Check valve does not work.

E.

Replace the check valve.

F.

Airjets are clogged.

F.

Use a small between-the-teeth

dental brush and white vinegar.

Dip the brush in the vinegar, brush

the hole, rinse the brush in clean

water, and then use the wet rinsed

brush to rinse the hole.

6.

Blower motor runs but no

air bubbles are observed.

A.

Blower motor inlet is blocked.

A.

Clean blower motor inlet.

B.

Airjets are clogged.

B.

Use a small between-the-teeth

dental brush and white vinegar.

Dip the brush in the vinegar, brush

the hole, rinse the brush in clean

water, and then use the wet rinsed

brush to rinse the hole.

C.

Check valve does not work.

C.

Replace the check valve.

D.

Blower motor does not work.

D.

Replace the blower motor.

7.

Blower motor operates,

air bubbles are observed,

but speed feature does

not work.

A.

Blower motor inlet is blocked.

A.

Clean blower motor inlet.

B.

Loose, disconnected, or

damaged wiring harness.

B.

Check wiring for proper

connections. Replace the wiring

harness if necessary.

C.

User keypad does not work.

C.

Replace the user keypad.

D.

Blower motor does not work.

D.

Replace the blower motor.

8.

Blower motor does not

turn off when the On/Off

button is pressed.

A.

User keypad does not work.

A.

Replace the user keypad.

B.

Loose, disconnected, or

damaged wiring harness.

B.

Check wiring for proper

connections. Replace the wiring

harness if necessary.

C.

Control does not work.

C.

Replace the control.

9.

Purge mode does not

work.

A.

User keypad does not work.

A.

Replace the user keypad.

B.

Control does not work.

B.

Replace the control.

10.

Bath does not purge

automatically.

A.

Blower does not work.

A.

Replace the blower.

1198326-2-A

14

Kohler Co.

Advertising