Warning, Important – Lennox International Inc. MPB35ST-NM User Manual

Page 3

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

3

Burn-in Period

During the fi rst few fi res of this appliance
there will be some odor due to the curing of
paint and burning off of lubricants used in the
manufacturing process.

Depending on your use, the burn-in period may
take a few hours or a few days.

Test gauge connections are provided on the front
of the millivolt gas control valve, identifi ed IN for
the inlet and OUT for the manifold side (see Fig-
urex 2
on Pagex 4 ). A 1/8" NPT Test gauge con-
nection is provided at the inlet and outlet side of
the electronic gas control valve (see Figurex
3
on Pagex 5).

These appliances and their individual shut-off
valves must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures greater
than
1/2 psig (3.5 kPa).

These appliances must be isolated from the
gas supply piping system (by closing their
individual manual shut-off valve
) during any
pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig (3.5 kPa).

Orifi ce Sizes - Sea Level to High Altitude
(All Models)

These appliances are tested and approved for
installations at elevations of 0-4500 feet (0-1372
meters) above sea level using the standard burner
orifice sizes (marked with an "*" in Table 6 ).
For elevations above 4500 feet, these appliances
must be properly "derated" by the gas supplier
or qualifi ed service technician (usually done at
the time of installation).

Note: Derated (defi nition) - Replacing burner
orifi ce with a smaller one to reduce BTU input.
The installation of this appliance must be accord-
ing to the regulations of the local authorities
having jurisdiction and, in the USA, the National
Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest
edition or, in Canada, the CAN1-B149.1 and .2
codes - latest edition.

Burner Orifi ce Sizes (all models)

Elevation

Feet (meters)

Natural

Gas

drill size (inches)

Propane

Gas

drill size (inches)

0-4500

(0-1372)

#37 (.104")

*

24M1001 •

1.55 mm (.061")

*

42M7901 •

* Standard size installed at factory
• Part /Cat. Number

Table 6

WARNING

Failure to comply with the instal-
lation and operating instructions
provided in this document will
result in an improperly installed
and operating appliance, voiding
its warranty. Any change to this
appliance and/or its operating
controls is dangerous. Improper
installation or use of this appli-
ance can cause serious injury or
death from fi re, burns, explosion
or carbon monoxide poisoning.

WARNING

Do not use these appliances if
any part has been under water.
Immediately call a qualifi ed,
professional service technician
to inspect the appliances and to
replace any parts of the control
system and any gas controls
which have been under water.

WARNING

If the information in this
manual is not followed
exactly, a fi re or explosion
may result causing prop-
erty damage, personal
injury or loss of life.

IMPORTANT

These appliances must not be
connected to a chimney or fl ue
serving a separate solid fuel
burning appliance.

KEEP YOUR HOUSE WELL VENTILATED
DURING THE CURING PROCESS. THE ODOR
AND HAZE EMITTED BY THE CURING PROCESS
CAN BE QUITE NOTICEABLE AND MAY SET OFF
A SMOKE DETECTOR.

A white fi lm may develop on the glass front
during the fi rst few fi res as part of the curing
process. The glass should be kept clean during
the fi rst two weeks of use to prevent the fi lm from
baking on (making it very diffi cult to remove).
See Glass Cleaning on Page 8.

SAFETY & WARNIING INFORMATION

WARNING

Do not attempt to alter or modify
the construction of the appli-
ance or its components. Any
modifi cation or alteration may
void the warranty, certifi cation
and listings of this unit.

WARNING

Improper installation, adjust-
ment, alteration, service or
maintenance can cause injury
or property damage. Refer to
this manual. For assistance or
additional information consult
a qualifi ed installer, service
agency or the gas supplier.

WARNING

These fireplaces are vented
heaters. Do not burn wood or
other material in these appli-
ances.

WARNING

This appliance is only for use
with the type of gas indicated on
the rating plate. This appliance
is not convertible for use with
other gases, unless a certifi ed
kit is used.

WARNING

Children and adults should be
alerted to the hazards of high
surface temperatures. Use
caution around the appliance
to avoid burns or clothing igni-
tion. Young children should be
carefully supervised when they
are in the same room as the
appliance.

Note: An Optional Screen Heat
Guard for the glass is available
(see Page 15 for ordering infor-
mation).

Advertising