Caution, Warning, Wiring diagrams – Lennox Hearth EBVSTNM-B User Manual

Page 18: Not for use with solid fuel, Product reference information, Replacement parts

Advertising
background image

18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

* Control Switches: Wall On/Off Switch or Timer, Unit Mounted On/Off Switch, or Remote Control Switch. If an optional control switch is installed, turn the appliance-

mounted ON/OFF burner control switch to the OFF position.

VERIFY PROPER OPERATION AFTER SERVICING.

If any of the original wire as supplied must be replace, it
must be replaced with type AWM 105° C - 18 gage wire.

Schematic Representation Only

ATTENTION: AU MOMENT DE L'ENTRETIEN

DES COMMANDES, ÉTIQUETEZ TOUS

LES FILS AVANT DE LES DÉBRANCHER.

DES ERREURS DE CÁBLAGE PEU-VENT

ENTRAÎNER UN FONCTIONNEMENT

INADÉQUAT ET DANGEREUX.

LENNOX HEARTH PRODUCTS

1508 Elm Hill Pike, Suite 108

Nashville, TN 37210

visit us at www.LennoxHearthProducts.com

1-800-655-2008

PRODUCT REFERENCE INFORMATION

We recommend that you record the following

important information about your fireplace.

Please call Lennox Hearth Products for the

phone number of your nearest Lennox Hearth

Products dealer who will answer your questions

or address your concerns.

Your Fireplace's Model Number ___________________________________________

Your Fireplace's Serial Number ___________________________________________

The Date On Which Your Fireplace Was Installed ______________________________

The Type of Gas Your Fireplace Uses _______________________________________

Your Dealer's Name ___________________________________________________

Parts will be shipped at prevailing prices at

time of order.

When ordering repair parts, always give the

following information:

1. The model number of the appliance.

2. The serial number of the appliance.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the appliance.

If you encounter any problems or have any

questions concerning the installation or ap-

plication of this system, please contact your

dealer or distributor.

REPLACEMENT PARTS

A complete parts list is found at the end of

this manual. Use only parts supplied from the

manufacturer.

With proper care and maintenance, your appli-

ance will provide many years of enjoyment. If

you should experience any problem, first refer

to the troubleshooting guide in this manual. If

problem persists, contact your Lennox Hearth

Products dealer or distributor.

Normally, all parts should be ordered through your

Lennox Hearth Products distributor or dealer.

WIRING DIAGRAMS

Wiring diagrams are provided here for reference

purposes only. This information is also provided

on schematics attached directly to the appliance

on a pullout panel located within the control

compartment.

CAUTION: LABEL ALL WIRES

PRIOR TO DISCONNECTION WHEN

SERVICING CONTROLS. WIRING

ERRORS CAN CAUSE IMPROPER

AND DANGEROUS APPLIANCE

OPERATION.

HIGH LIMIT SWITCH

CONTROL SWITCH*

GAS CONTROL VALVE

TERMINALS

THERMOPILE

HI

L O W

PILO

T

PIL

OT

ON

ti

OFF

IN

OUT

TH

TP

HT

PT

NOTES:

1. If any of the original wire as supplied must be replaced, use Type AWM 105°C - 18 gage wire ONLY.

2. 120 VAC, 60 Hz - Less than 3 Amps.

CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and

dangerous operation. Verify proper operation after servicing.

0.375"

0.375"

0.25" Ø

NOT FOR USE WITH SOLID FUEL

CAUTION:

Hot while in operation. Do not

touch. Severe Burns may result. Keep children, clothing,

furniture, gasoline and other liquids having flammable

vapors away.

CAUTION:

Do not operate the appliance with

factory installed refractory panel(s) removed, cracked or

broken. Replacement of the factory installed refractory

panel(s) should be completed by a licensed or qualified

service person.

WARNING:

Improper installation, adjustment,

alteration, service or maintenance can cause injury

or property damage. Refer to the owner’s information

manual provided with this appliance. For assistance

or additional information consult a qualified installer,

service agency or the gas supplier.
Due to high temperatures, keep children, and furniture

away.
Keep burner and control compartment clean. See

installation and operating instructions accompanying

appliance.

WARNING:

Do not connect 120 V AC to the control valve.

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE

WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE

NATIONAL FUEL GAS CODE, ANSI Z223.1, OR NATURAL

GAS AND PROPANE INSTALLATION CODE, CSA B149.1.

If not installed, and maintained in accordance with the

manufacturer's instructions, this product could expose

you to substances in fuel or fuel combustion which are

known to the state of California to cause cancer, birth

defects, or other reproductive harm.

* For a copy of the homeowner’s care and operation

manual, go to www.lennox.com or call 1-800-9-lennox.

B-VENTED APPLIANCES NEED FRESH AIR FOR SAFE

OPERATION AND MUST BE INSTALLED SO THERE

ARE PROVISIONS FOR ADEQUATE COMBUSTION AND

VENTILATION AIR.

DIRECT VENTED APPLIANCES MUST NOT BE OPERATED

WITHOUT THE FRONT GLASS PANEL(S) INSTALLED.

DO NOT OPERATE APPLIANCE WITH BROKEN,

CRACKED OR MISSING GLASS DOORS OR ENCLOSURE

PANEL(S).

ELECTRONIC IGNITION WIRING DIAGRAM

P/N 62L2701_4

Optional Blower**

OFF/ON Switch

(Integral with

Gas Valve)

Honeywell

Electronic

Gas

Valve

120 VAC

Primary

Secondary

Junction Box

Break Off Tab

Junction Box

Pilot Burner

Assembly

BL

BL

Field Wired
Factory

Wired

BK = BLACK BL = BLUE

R = RED W = WHITE

G = GREEN

BK

BK

BK

BK

BL

R

GROUND

24 V

Transformer

J-Box Wiring

WITH Optional Blower Switch

J-Box Wiring

WITHOUT Optional Blower Switch

BK

W

G

CA

V

02

1

BK

W

G

CA

V

02

1

Igniter

Connector

*

**

Control Switches: Wall On/Off

Switch, Unit Mounted On/Off Switch,

Wall Thermostat (Direct-Vent Units

Only) or Remote Control Switch.

Some models are not approved for

use with an optional blower. See Care

and Operation manual for approved

accessories.

Schematic Representation Only

W

GR

BK

BK

R

Control

Switch *

DAMPER

SWITCH

HIGH LIMIT

SWITCH

B-Vent appliances only - one or both of these switches must

be factory installed in series as shown. If wires to these switches

are replaced, wires must be Type AWM 200°C - 18 gage wire ONLY.

NOTES:

1. If any of the original wire as supplied

must be replaced, use Type AWM

105°C - 18 gage wire ONLY.

2. 120 VAC, 60 Hz - Less than 3 Amps.

CAUTION: label all wires prior to

disconnection when servicing controls.

Wiring errors can cause improper and

dangerous operation. Verify proper

operation after servicing.

ELECTRONIC IGNITION WIRING DIAGRAM

0.375"

0.375"

0.25" Ø

NOT FOR USE WITH SOLID FUEL

CAUTION:

Hot while in operation. Do not

touch. Severe Burns may result. Keep children, clothing,

furniture, gasoline and other liquids having flammable

vapors away.

CAUTION:

Do not operate the appliance with

factory installed refractory panel(s) removed, cracked or

broken. Replacement of the factory installed refractory

panel(s) should be completed by a licensed or qualified

service person.

WARNING:

Improper installation, adjustment,

alteration, service or maintenance can cause injury

or property damage. Refer to the owner’s information

manual provided with this appliance. For assistance

or additional information consult a qualified installer,

service agency or the gas supplier.
Due to high temperatures, keep children, and furniture

away.
Keep burner and control compartment clean. See

installation and operating instructions accompanying

appliance.

WARNING:

Do not connect 120 V AC to the control valve.

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE

WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE

NATIONAL FUEL GAS CODE, ANSI Z223.1, OR NATURAL

GAS AND PROPANE INSTALLATION CODE, CSA B149.1.

If not installed, and maintained in accordance with the

manufacturer's instructions, this product could expose

you to substances in fuel or fuel combustion which are

known to the state of California to cause cancer, birth

defects, or other reproductive harm.

* For a copy of the homeowner’s care and operation

manual, go to www.lennox.com or call 1-800-9-lennox.

B-VENTED APPLIANCES NEED FRESH AIR FOR SAFE

OPERATION AND MUST BE INSTALLED SO THERE

ARE PROVISIONS FOR ADEQUATE COMBUSTION AND

VENTILATION AIR.

DIRECT VENTED APPLIANCES MUST NOT BE OPERATED

WITHOUT THE FRONT GLASS PANEL(S) INSTALLED.

DO NOT OPERATE APPLIANCE WITH BROKEN,

CRACKED OR MISSING GLASS DOORS OR ENCLOSURE

PANEL(S).

ELECTRONIC IGNITION WIRING DIAGRAM

P/N 62L2701_4

Optional Blower**

OFF/ON Switch

(Integral with

Gas Valve)

Honeywell

Electronic

Gas

Valve

120 VAC

Primary

Secondary

Junction Box

Break Off Tab

Junction Box

Pilot Burner

Assembly

BL

BL

Field Wired
Factory

Wired

BK = BLACK BL = BLUE

R = RED W = WHITE

G = GREEN

BK

BK

BK

BK

BL

R

GROUND

24 V

Transformer

J-Box Wiring

WITH Optional Blower Switch

J-Box Wiring

WITHOUT Optional Blower Switch

BK

W

G

CA

V

02

1

BK

W

G

CA

V

02

1

Igniter

Connector

*

**

Control Switches: Wall On/Off

Switch, Unit Mounted On/Off Switch,

Wall Thermostat (Direct-Vent Units

Only) or Remote Control Switch.

Some models are not approved for

use with an optional blower. See Care

and Operation manual for approved

accessories.

Schematic Representation Only

W

GR

BK

BK

R

Control

Switch *

DAMPER

SWITCH

HIGH LIMIT

SWITCH

B-Vent appliances only - one or both of these switches must

be factory installed in series as shown. If wires to these switches

are replaced, wires must be Type AWM 200°C - 18 gage wire ONLY.

NOTES:

1. If any of the original wire as supplied

must be replaced, use Type AWM

105°C - 18 gage wire ONLY.

2. 120 VAC, 60 Hz - Less than 3 Amps.

CAUTION: label all wires prior to

disconnection when servicing controls.

Wiring errors can cause improper and

dangerous operation. Verify proper

operation after servicing.

J-Box Wiring

Advertising