Honeywell electronic gas valve, Sit millivolt gas valve – Lennox Hearth EBVSTNM-B User Manual

Page 9

Advertising
background image

9

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 3

Honeywell Electronic

Gas Valve

Figure 2

Note: The piezo igniter is located on the modesty panel - refer to Figure 1.

Variable Flame Height Adjustment
( Millivolt Appliances only)

All Millivolt appliances are equipped with a

variable gas control valve. Flame height for

these models may be adjusted through a range

between fixed low and high settings, alternately,

while the appliance is in operation.

Adjust the flame height as desired after lighting

the appliance by rotating the variable adjustment

control knob located on the front of the valve

(refer to Figure 2). (An extension is provided to

this knob so that the adjustment may be made

at the modesty panel).

HI

LO W

TPTH

TP

TH

PILO

T

PIL

OT

ON

it

OFF

Variable Flame Height Adjustment

Manifold Pressure Port

Inlet Pressure Port

Main Gas

Control Knob

IN

OUT

SIT Millivolt Gas Valve

ON/OFF Switch

Electronic

Gas Control

Valve

Inlet

Pressure

Port

Manifold Pressure Port

OFF

IN

P

S

I

ON

CONTROL

IG

N

IT

ER

Outside Combustion Air Controls

Many appliances are equipped, when installed,

with an outside (make-up air) vent system

that is designed to provide the appliance with

outside make-up air for combustion when

in operation. The outside air control lever

for the outside air system is standard on all

appliances but should not be operated if the

complete system is not installed. Refer to

Figure 4. When the complete outside air vent

system is installed, the installer will remove

the securing screw from the combustion air

control lever located on the right side of the

fireplace opening.

If the securing screw has not been removed

and you have reason to believe that you have

a complete outside air system, contact your

distributor to have your appliance inspected for

the presence of the complete system. DO NOT

assume that you have this system in place.

Outside Air Control Lever

and Securing Screw Location

(EBVST and EBVPF Units Shown)

Figure 4

Outside Air Control Lever with Stop Behind

Securing Screw

Outside Air Shutter in the

Closed Position

Control Compartment Access Panel

Advertising